6
The AC mains fuse is located on the rear of the RPS11 unit next to the AC mains connector. In the event of a mains surge or
under-rated fuse value, the mains input fuse will rupture. Switch off the power supply and remove the mains lead plug from the
“AC MAINS IN” socket on the rear of the unit.
Check the fuse and replace if necessary. Check also the AC mains input voltage setting is correct for the mains supply in your
area before switching the unit on again.
TO AVOID THE RISK OF FIRE REPLACE FUSE WITH THE CORRECT TYPE ONLY, AS
INDICATED ON THE UNIT
In the event of repeated failure of the mains fuse, consult the local dealer from where the unit was purchased.
AC MAINS VOLTAGE SETTING
FUSE RATING
220/230 VAC
T 3.15A / 250V
100/120 VAC
T 5.0A / 250V
Technical Specification
Mains Input Voltage Settings
230/220/120/100 VAC @ 47-63 Hz
Power
consumption
(max.)
300W
Mains
Fuse
Rating
DC
Fuse
Rating
100-120 V~ Use T 5.0A/250V
V+, V-
Use T 10A/250V
220-240 V~ Use T 3.15A/250V
+48V
Use T 2.5A/250V
Outputs
DC Voltage Rail
Output Current
+16 VOLTS
5A Max.
-16 VOLTS
5A Max.
+48 VOLTS
200mA Max.
DC Output Socket Pin Connections
Pin 1 = +16 Volts
Pin 3 = -16 Volts
Pin 4 = CHASSIS 0V
Pin 5 = AUDIO 0V
Pin 10 = +48 Volts
Pins 2, 6, 7, 8, 9, = not connected
Overall
Dimensions
Front
Panel
Chassis
(Maximum
External)
19 inch 3U (482mm x 133mm)
Height: 135mm including feet (5.31 inches)
Width:
419mm
(16.50
inches)
Depth: 235mm (9.25
inches)
Weight : 9.5Kg
(21
pounds)