background image

 

ALLEN

&

HEATH

    

iLive-R72 service manual               AP7893

 

_3    3            

 

  

 Servicing Precautions – General Notes 

 

Service personnel:

   

Service work should be carried out by technically qualified service personnel 
only.  Mains power is dangerous and can kill.  Do not attempt to work on a line-
ar or switched mode power supply if you are not suitably qualified to do so.  Do 
not attempt to repair surface mount circuit assemblies unless you are suitably 
qualified and have the necessary facilities to do so.  Replacement circuit as-
semblies can be ordered. 

Service facilities:

   

Ensure a suitably sized work surface is available.  Ensure this is clear of dirt, 

debris and obstructions which may damage the equipment surfaces.  Ensure 
adequate lighting.  Use the correct tools for the job and ensure they are in good 
working order.  Ensure all workshop safety requirements are adhered to. 

Service information: 

Check that you have all the information you need before starting the service 

job.  Refer to the Allen & Heath web site or contact Allen & Heath technical 
support for details on the latest information.  Full technical information can be 
downloaded from the web site Distributor Zone (password required). 

Mains power:

 

 

Connect the equipment to mains power only of the type described in the user 

guide and marked on the rear panel.  The power source must provide a good 
ground connection.  Ensure you always use an isolation transformer when 
working on any mains power supply unit. 

Mains cord and fuse:

 

 

Use the correct power cord as supplied with the equipment.  Do not remove or 

tamper with the ground connection in the power cord.  Heed the Important 
Mains Plug Wiring Instructions printed in the user guide if it is necessary to re-
wire the mains cord.  Always replace the equipment mains fuse with the correct 
type and rating as described in the user guide and marked on the equipment 
panel. 

Opening the unit:

   

Switch off and remove the mains power cord before opening the equipment.  

Ensure all power supply covers and safety shields are in place before applying 
power with the unit open for diagnostic fault finding. 

Closing the unit:

 

 

Before finishing, check the quality and accuracy of the service work carried out.  

Remove any dirt or debris as this may cause equipment failure in the future.  
Ensure all assemblies, harnesses and connectors are correctly aligned and 
plugged in.  Ensure that jumper settings and control configurations are correctly 
set according to the requirements of the customer. 

Continued - 

Содержание iLive -R72

Страница 1: ...EATH iLive R72 service manual AP7893 _3 1 Copyright 2011 Allen Heath Limited All rights reserved Allen Heath Limited Kernick Industrial Estate Penryn Cornwall TR10 9LU UK ALLEN HEATH Service manual iL...

Страница 2: ...quipment has been installed and operated in accordance with the instructions in this User Guide The equipment has not been subject to misuse either intended or accidental neglect or alteration other t...

Страница 3: ...ributor Zone password required Mains power Connect the equipment to mains power only of the type described in the user guide and marked on the rear panel The power source must provide a good ground co...

Страница 4: ...ned flight case if you need to ship the unit To avoid injury to yourself or damage to the equipment take care when lifting moving or carrying the equipment Operation To test the console make sure it i...

Страница 5: ...ALLEN HEATH iLive R72 service manual AP7893 _3 5 001 Remove rear screws 002 Remove plastic trims and side screws 003 Remove front screws Separate front panel from base panel...

Страница 6: ...ALLEN HEATH iLive R72 service manual AP7893 _3 6 004 Remove side panels and put R72 on its side 005 Cut cable ties and remove fader DC leads...

Страница 7: ...ALLEN HEATH iLive R72 service manual AP7893 _3 7 006 Disconnect large harness from 004 022 West PCB 007 Disconnect harnesses 008 Open R72...

Страница 8: ...ALLEN HEATH iLive R72 service manual AP7893 _3 8 009 Disconnect harness 010 Disconnect harness 011 Disconnect harness...

Страница 9: ...ALLEN HEATH iLive R72 service manual AP7893 _3 9 012 Disconnect LCD harness 013 Disconnect SBC harness 014 Disconnect LVDS cable...

Страница 10: ...ALLEN HEATH iLive R72 service manual AP7893 _3 10 015 Disconnect talkback PCB 016 Top and base are separate...

Страница 11: ...rs asp UK parts must be ordered through an appointed A H dealer or service centre A list of UK service centres can be viewed at http www allen heath com UK service_centres asp EXTERIOR PARTS Pot nut b...

Страница 12: ...A GREEN AJ7537 PUSH BTN SKPMA BLUE AJ 7398 push button guide with LED window AJ 7416 push button guide NO LED window Fan grill AA5359 Foot AK0102 Foot AK0102 Hole Plug AK7525 Lamp socket AL8104 Fan 00...

Страница 13: ...ALLEN HEATH iLive R72 service manual AP7893 _3 13 INTERIOR PARTS Bank L 004 018 Bank M 004 019 Bank R 004 020...

Страница 14: ...ALLEN HEATH iLive R72 service manual AP7893 _3 14 WEST Backlight TFT WEST BACKLIGHT 004 022 TFT EAST 004 023...

Страница 15: ...ALLEN HEATH iLive R72 service manual AP7893 _3 15 Talkback 004 024 Fader PSU Distribution 004 025...

Страница 16: ...ALLEN HEATH iLive R72 service manual AP7893 _3 16 Issue 1 2 ASSIGN AS T80 OR Issue 3 ASSIGN AS T80 OR T112 OR R72 iLive controller PCB 003 791 Fader slave 003 323...

Страница 17: ...ALLEN HEATH iLive R72 service manual AP7893 _3 17 PFL meter 003 543 Fader master 003 796...

Страница 18: ...ALLEN HEATH iLive R72 service manual AP7893 _3 18 Headphone 003 932 Channel PCB 004 021 Channel PCB 004 021 This part not used on R72...

Страница 19: ...ALLEN HEATH iLive R72 service manual AP7893 _3 19 PSU 004 026...

Отзывы: