DT164-W User Guide 

 

AP11870 Issue 1 

 

 

 

 

 

 

Top panel and power options 

 

 

 

 

 

Dante Secondary  

Can be set to Redundant mode or to Switched 

mode for connection to multiple devices, for example two mixing consoles. Set 

the port mode in Dante Controller. 

 

Dante Primary 

EtherCon port for connection to the Dante network. The 

cable carries the audio signals as well as preamp control data. 

 

Reset Network settings  

Hold down the recessed switch for 10 

seconds to reset the network settings for the DT164-W. This will delete any 

static IP address and revert to factory default (DHCP / zero-conf).

 

 

DC 12V Input  

Can be used instead of AC mains to power the unit 

where adequate DC distribution is provided in a building. Can also be used as 

a backup power supply in case of mains failure.

 

 

Mains power input  

The built-in universal PSU accepts voltages from 

100 to 240V AC 50/60Hz. A module with IEC inlet is fitted by default. An 

optional module is provided for permanent installation, with knockout holes to 
accept a cable gland. 

 

Replacement of the IEC AC inlet module and mains 

wiring for permanent installation must be performed by a 

qualified electrician. See instructions later in this guide. 

 

 

Содержание DT164-W

Страница 1: ... with your DT164 W unit Optional gland module part number 004 1097 for permanent AC mains wiring installation Mounting frame AH11504 for in wall or wall surface mounting 6x M4 6mm T20 screws AB2921 for mounting the DT164 W to the mounting frame Software and firmware Visit the Audinate website to learn more about Dante and download Dante Controller to route audio and configure devices on a Dante ne...

Страница 2: ...ces When a valid DT164 W socket is routed to a dLive SQ Dante card and patched to an Input channel the dLive SQ will present preamp gain 48V and Pad controls for the socket Use Dante Controller s Clock Status tab to select the Dante network master The DT164 W should always be slave on the Dante network with the mixer typically set to Preferred Master and Enable Sync To External Dante Primary netwo...

Страница 3: ...4 W This will delete any static IP address and revert to factory default DHCP zero conf DC 12V Input Can be used instead of AC mains to power the unit where adequate DC distribution is provided in a building Can also be used as a backup power supply in case of mains failure Mains power input The built in universal PSU accepts voltages from 100 to 240V AC 50 60Hz A module with IEC inlet is fitted b...

Страница 4: ... their Gain Pad and 48V are controlled from the network The 48V indicator detects voltage at the socket whether supplied by the DT164 W or received from an external source Output sockets Balanced XLR outputs operating at nominal 4dBu level Vents Ensure good ventilation at the front of the unit Avoid obstruction of vents while operating Avoid dirt or liquid ingress ...

Страница 5: ...t in place with the 6x M4 6mmT20 screws provided Flush mounting in a wall Use the mounting frame AH11504 in the orientation shown below Align the threaded inserts on the sides of the DT164 W with the frame and secure the unit in place with the 6x M4 6mm T20 screws provided Connect the power and Cat5 cable s then fix the assembly to the wall using appropriate fixings or screws for the type of wall ...

Страница 6: ...ng a Torx T8 driver Pull out the module and unplug the harness at the bottom of the assembly Fit a suitable cable gland or grommet appropriate to the cable wire size to the gland module plate Run the mains cable through the gland Minimum cable size 0 75mm2 or 20 AWG Wire the mains cable to the terminal connector on the gland module paying attention to polarity and earth grounding as indicated on t...

Страница 7: ...ON The mains supply disconnect device is the installation all pole circuit breaker or the switched fused outlet which must be labelled and must be accessible so as to be readily operable when the appliance is in use Dimensions 87 00 210 00 210 00 120 84 ...

Страница 8: ...t 12V DC 3A max Operating Temperature Range 0 C to 40 C 32 F to 104 F Dimensions and Weight Width x Depth x Height x Weight DT164 W 210 x 87 x 210 mm x 3 2kg 8 25 x 3 5 x 8 25 x 7lbs Read the Safety Instructions Sheet included with the product and the information printed on the panel before operating A limited one year manufacturer s warranty applies to this product the conditions of which can be ...

Отзывы: