Allegion 8310816 Скачать руководство пользователя страница 5

75.0022.01 ALLEGION 8310-816 TOUCHLESS ACTUATORS 20200612   

Page 5 of 8

Sensor erratically 
detecting or falsely 
activating

Not properly grounded

Verify continuity between sensor ground and 
earth ground.  
See Application Note for details.

Unstable power supply

Ensure the isolation module (polarity-sensitive) 
is being used with each 8310-816.

Electrical noise within 
sensing zone

Reduce sensing zone (potentiometer 
counterclockwise).

Non-stationary object 
within detection zone

Clear a 10” zone around detection field.

Sensor not detecting

Sensing zone is set 
too low

Increase sensing zone (potentiometer 
clockwise).

No power

Verify power supply and connection.

TROUBLESHOOTING

The sensor manufacturer cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, the sensor 
manufacturer does not guarantee any use of the sensor outside of its intended purpose.
The sensor manufacturer strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for 
doors/gates, and factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor 
system installation is compliant with local, national, and international regulations, codes, and standards. 
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations 
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices.  Safety inspections must be performed during each service 
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107). 
Verify that all appropriate industry signage and warning labels are in place. 

INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS

Содержание 8310816

Страница 1: ...nsing Zone 0 4 Sensing Zone is dependent upon size area of object orientation of object speed of object and environmental conditions Relay 1 Form A Solid State Relay 0 4A 60 VAC VDC max Dimensions 0ve...

Страница 2: ...WIRING and 3 SETTINGS ADJUSTMENTS must be completed prior to continuing installation Section 4 Single Swing Doors Dual Egress Swing Doors Sim Pair Swing Doors Sliding Doors INSTALLATION Only trained...

Страница 3: ...once powered DOOR HEADER GREEN YELLOW GREEN YELLOW RED BLACK WHITE RED BLACK WHITE GREEN BLUE Installer Provided Wire Harness ISOLATION MODULE RED BLACK WHITE GREEN BLUE WIRE NUT NO COM POWER POWER N...

Страница 4: ...two 2 set screws 14 Test the installation functionality and performance CAUTION When installing near unprotected and or uninsulated circuits additional electrical isolation may be needed The shrink tu...

Страница 5: ...e of the sensor outside of its intended purpose The sensor manufacturer strongly recommends that installation and service technicians be AAADM certified for pedestrian doors IDA certified for doors ga...

Страница 6: ...Page 6 of 8 75 0022 01 ALLEGION 8310 816 TOUCHLESS ACTUATORS 20200612 75 0022 01 ALLEGION 8310 816 TOUCHLESS ACTUATORS 20200612 Page 7 of 8...

Страница 7: ...please contact Allegion at 1 877 671 7011 If you must wait for the following workday to call Allegion leave the door inoperable until satisfactory repairs can be made Never sacrifice the safe operatio...

Отзывы: