3
A
B C
Page 4 of 8
75.0022.01 ALLEGION 8310-816 TOUCHLESS ACTUATORS 20200612
(A) SENSING ZONE
–
potentiometer
COUNTERCLOCKWISE – decrease (0’’ minimum)
CLOCKWISE – increase (4’’ maximum)
1
(B) AUDIBLE ALERT
– DIP-switch 1 (left)
ON – audible alert pulsed for 0.5 seconds during detection
OFF – audible alert off
(C) LED
– DIP-switch 2 (right)
ON – LED on at rest, pulsed off for 0.5 seconds during detection
OFF – LED off at rest, pulsed on for 0.5 seconds during detection
SETTINGS & ADJUSTMENTS
NOTES:
1. Maximum Sensing Zone will vary depending on size (area), orientation, and speed of object as well as environmental conditions.
4
INSTALLATION (cont.)
11. Reinstall the back of the NEMA 4 enclosure.
12. Reassemble (i.e. align, push in, and slide down) the faceplate assembly to the mounting ring.
13. Reinstall the two (2) set screws.
14. Test the installation functionality and performance.
CAUTION:
When installing near unprotected and/or uninsulated circuits, additional
electrical isolation may be needed. The shrink tubing over the printed wiring
board is rated minimum 150V, VW-1, and 80
°
C. This information may be
taken into account to define whether additional isolation is required.
FUNCTIONALITY
ACTIVATION
Activation signal held until sensing zone is cleared (or relearned). Audible Alert (if enabled)
will pulse for 0.5 seconds at initial detection.
REJECTION
An object must be within sensing zone for at least 130 milliseconds for detection to occur
(i.e. parallel traffic rejection).
TRACKING
Reduced unwanted detections by allowing small variations in baseline capacitance (e.g.
temperature/humidity changes). If stationary object remains within sensing zone for more
than 5 seconds, a new capacitive zone will be learned and normal operation will resume
(e.g. chewing gum stuck to faceplate).