17
Owner’s Manual
Compressor (cont’d)
ELECTRICAL POWER REQUIREMENTS (cont’d)
This product is for use on a nominal 110 volt circuit. An outlet having the
same configuration as the plug. No adapter should be used with this product.
Do not alter the plug to fit into a non–Ground or 2-slot receptacle.
WARNING! IMPROPER INSTALLATION OF THE GROUNDING PLUG
CAN RESULT IN A RISK OF ELECTRIC SHOCK. IF REPAIR OR
REPLACEMENT OF THE CORD OR PLUG IS NECESSARY, DO NOT
CONNECT THE GROUNDING WIRE TO FLAT BLADE TERMINAL.
THE WIRE INSULATION HAVING AN OUTER SURFACE THAT IS GREEN
WITH, OR WITHOUT, YELLOW STRIPES IS THE GROUNDING WIRE.
Extension Cord
Use the chart on the right for
the proper extension cord length.
Use only a 3-wire extension cord
that has a 3-blade grounding plug
and a 3-slot receptacle that will
accept the plug of the product. Make
sure your extension cord is in good
condition. An undersized cord will
cause a drop in line voltage as well
as a loss of power and overheating.
The smaller the guage number, the
heavier the cord.
Grounding Instructions
This product is equipped with a cord having a grounding wire an
appropriate grounding plug. The plug must be plugged into an outlet
that is properly installed and grounded in accordance with all local codes
and ordinance.
AMP
RATING
LENGTH OF
CORD IN FEET
(120 Volts)
10-12
12-14
14-16
16-18
18-20
25’
16
16
16
14
14
50’
14
12
12
12
12
100’
10
10
10
8
8
150’
8
8
8
8
8
Meijer.com