Storage of the appliance and gas cylinders 

Always store the appliance in a clean and dry environment. The best way to store is hanging side wards on a hook on the wall. This way 
avoids the risk of damaging the burners. Placing the appliance (carefully) side wards resting on the burner reflectors is not advised while 
the risk of damage sooner or later is likely. For short-time-storage no further special precautions are needed. For long time storage put a 
plastic bag over each burner and close it around the safety device so no dust or insects can enter the appliance. Make sure that the 
appliance is cooled down before storing it. Always disconnect the appliance from the gas supply. 
Take into account your local requirements for storage of the gas bottles. In most places it is only allowed outside or in a well ventilated 
area. Your local fire department or gas supplier can inform you about the regulations. 
 

Fault finding 

Problem 

Action 

Burner does not light 

- Check if gas valve of the gas cylinder or gas line is open 
- Check if gas cylinder is empty 
- First ignition will take up to 30-60 seconds before gas is available 
- Check if the injector is blocked 
- Check if the gas pressure is identical to the pressure indicated on the dataplate 

Burner extinguishes after lighting 

- Keep button safety device pressed for a longer period (up till 20 seconds) 
- Thermocouple or magnetic coil is broken. Contact a gas repair company or gas installer 
- Check if both burner stones are ignited.  

Flames  leave  the  confines  of  the  burner 
or are sooting 

-  Gas  pressure  is  too  high.  Check  use  of  correct  pressure  regulator  or  check  if  the  gas 
pressure regulator is broken. 
- Wrong gas is used. Check data plate for the correct gas supply 

The burner is only partly glowing 

- Wrong gas is used. Check data plate with the gas supply 
- Check if the injector or venturi are blocked or dirty 

The  burner  makes  a  lot  of  noise  after 
ignition or after several minutes 

- Wrong gas is used. Check data plate with the gas supply 
- Check if the burner stone is broken or damaged 

The  burner  ring  does  not  fit  anymore 
properly in the brackets. 

- The parasol is opened in a different position every time. Mark the opening position so that 
the parasol will be opened every time in the same way.  

 

Declaration of conformity 

We, Alke B.V., located in Scherpenzeel, The Netherlands, hereby declare that this product complies with the following EU directives: 
 
Directive on appliances burning gaseous fuels (90/396/EEC) 
 
Scherpenzeel, 05-04-2005 
 
Adri van Alphen 

 

 

 

Derk Jan Keurhorst  

Managing Director   

 

 

Managing Director 

 
For  spare  parts,  service  material,  advice  and  information  please  contact  your  distributor  of  this  appliance.  Service  parts  are  only 
available via your distributor. For general manufacturers information please see the internet: www.alke.nl 
 

10  Technical table (see next page) 

 
First read the technical table to find the references to the remarks written below.   
 
(*) Weight is the standard SR model inclusive mounting brackets but without hose and gas regulator. For the DR model add another 2,5 
kg. 
 
(**) The combination category, gas supply pressure and countries of destination are selected for the European standards EN 14543, EN 
461 and EN 437. These standards give the official situation per country. But their listing is not always complete and sometimes unclear 
and  in  contradiction  with  each  other.  In  some  countries  the  situation  locally  can  be  different  from  the  official  information  or  the 
information is even not available. Our advice is to stay first with the official listing as given in the table above. In other cases, check with 
your local gas authorities the data plate of the appliance to determine if the appliance can be used safely in your specific situation. 
 
(***) Not specified as a standard pressure, but until now all countries accept this as long as the regulator is supplied with the appliance.   
 
Product Identification Number CE approval (issued by Gastec Certification BV): PIN: 0063BO3251  
 
 
 

(stamp dealer) 
 
 
 
 
 
 
 

 

 

Содержание PH-4

Страница 1: ...277 30 80 Email info alke nl Version June 2009 Manual number 0009 0201EN Users and Installation Manual Patio Heater PH 4 and PH 8 Bracket mounting for round and square types of parasols with 8 ribs Ch...

Страница 2: ...2 Fig 1a Fig 1b Fig 2a Fig 2b Fig 2c Fig 2d Fig 2e Fig 2f Fig 3a Fig 3b Fig 3c Fig 4a...

Страница 3: ...3 Fig 4b Fig 5a Fig 5b Fig 6 Fig 7a Fig 7b Fig 7c Fig 7d Fig 8a Fig 8b Fig 8c...

Страница 4: ...4 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15 Fig 16 Fig 17 Fig 18 Fig 19 Fig 20...

Страница 5: ...sol Heater with 4 ceramic burner stones up to 5 9 kW depending gas type PH 8 Parasol Heater with 8 ceramic burner stones up to 10 2 kW depending gas type The following suffixes are used in combination...

Страница 6: ...s with the hooks completely around the central burner ring of the appliance fig 4b Tighten the bolts and nuts a bit more so the appliance will stay in place without help Check from a distance if the b...

Страница 7: ...cylinder is changed but at least once a month Avoid twisting or stress of the gas hose Twisting or stress will shorten the live time of the gas hose During inspection check the hose for damage splitti...

Страница 8: ...ew seconds Fig 11 number 2 Note When the appliance is ignited for the first time or after storage for a period ignition of the first burner will take some time because it takes a while before the air...

Страница 9: ...a lot of noise after ignition or after several minutes Wrong gas is used Check data plate with the gas supply Check if the burner stone is broken or damaged The burner ring does not fit anymore prope...

Страница 10: ...ane propane 1 20 4 80 kW 1 10 4 40 kW 350 gr h 0 54 mm No 5 7 kg 91 x 16 cm I3B 30 mbar G30 LPG butane 1 20 4 80 kW 1 10 4 40 kW 350 gr h 0 54 mm No 5 7 kg 91 x 16 cm PH 8 I2L 25 mbar G25 natural gas...