background image

INSTALLATION 

k_see  '

D  I G  ETA  L  WATE  R  IO  N  IZE  R

Faucet  Type  : External  Screwed

Faucet  Type  : Internal  Screwed

Faucet

Aerator

ON/OFF 

Swivel

Water Faucet Diverter

Faucet

Aerator

Adaptor (optional)

ON/OFF 

Swivel

Water Faucet 

Dlverter

Source 

Water

Source 

Water Inlet Hose

Remove aerator from faucet,

Illa Pliers may be required.

X  If required, attach adaptor (2 sizes of adaptor are supplied for use) before attaching water faucet diverter to faucet.

XRemove  compression nut on the side of the water faucet diverter, attach Source Water Inlet Hose and tighten nut.

GD 

The following types of water tap is NOT compatible for standard faucet installation

If you are using any of the followings, please ensure the water tap is replaced before faucet installation can be proceeded.

:C

O

I

Shower nozzle

Square 

spout

Oval spout

Spout external

diameter more

than 24 mm

Spout less than

15 mm in height

Pull-down

sprayer

Tap with sensors

Cut the Water Drain Hose to length and direct it to the sink for

draining or collection of water output.

tile You can use the Hose-fixation holder to keep the Drain Water Hose

in place.

Maintain the lenght of drain water hose within 2 metres so as to allow natural drainage flow rate. Water outflow may
be suspended if the water outlet hose is steeped in water inside a container or if the hose is unnecessarily long.

>  Do  not lift the  drain water  hose above  the  bottom  of the  unit. This will  hinder the water  drainage  and  may

cause internal damage to the unit,

Содержание AMS 4100

Страница 1: ...DIGITAL WATER IONIZER AMS 4100AMS 41005 Operation Manual fence...

Страница 2: ...PACKAGECONTENTS HOWTO OPERATE HOW TO PRODUCEALKALINE IONIZEDWATER HOW TO PRODUCEACIDIC IONIZEDWATER HOWTO PRODUCEPURIFIEDWATER MELODYON OFF VOLUME ADJUSTMENT FILTERREPLACEMENT FILTERCOMPOSITION pH VAL...

Страница 3: ...of experience and knowledge unlessthey have been given supervision or instruction Children must be supervised not to play with this appliance For boner drinking Always discard the intial dispensed wa...

Страница 4: ...ble it may cause an electric shock or If the supplied cord is damaged it must be replaced by the manufacturer it s service agent or qualified persons Please refer this condition to your seller and enf...

Страница 5: ...before the Ist hand operation of the unit after installation Never allow hot water input into the unit This may cause severe damage to it s interior especially the filter and ionization chamber Optimu...

Страница 6: ...lammable Do not use an Aluminum weak against alkaline liquid copper weak against acid or other metallic receptacle to store ionized water Glass or ceramic containers are recommended Do not drink ioniz...

Страница 7: ...uch Buttons 5 Operation Knob Water Supply Control Valve 6 Main PowerSwitch 7 Fuse Holder 8 Filter Connection Terminal A filtercartridgemustbe connectedto the terminal whenthefilterisreplacedwitha newo...

Страница 8: ...ppears when Purified water is chosen 10 Alkaline It appears when alkaline water is chosen 11 Water Inflow Rate Indicator Optimum flow rate 2 0 2 5 c min 12 InletWaterTemperatureindicator Optimumtemper...

Страница 9: ...uide paper on the intended location of the wall after slightly pasting the guide paper with water 2Drill holes into the wall on the wall stud position as shown in the guide paper and insert the screw...

Страница 10: ...ert it in the arrow direction A One touch fining View of safety key insertion Connect the hose to drain water outlet port and cut the other end of the hose to havesufficient length to reach the sink f...

Страница 11: ...installation If youare usingany of the followings pleaseensurethewatertap is replaced beforefaucet installationcan be proceeded C O I Showernozzle Square spout Ovalspout Spoutexternal diametermore tha...

Страница 12: ...spout arm has the two stage stretch and can be further extended horizontally if required X Pleasescrew Flexible Spout End clockwise into Outlet Cap noleugmly tp Pie sew d not overtighten X Pleaseinser...

Страница 13: ...DC WAVE MELODY OFF ON Dmin Water Outlet H7e One touch Fining Safety Key Source Water Inlet Hose Screws and Holders Fuse Water Diveer W Check Valve M Accessories are subject to change depending on the...

Страница 14: ...imum inflow rate is 2 0 2 5 litres min Adjust the water inflow rate by using the operation knob The screen backlight color will be varied according to the chosen function and pH level OF 1 Rotate the...

Страница 15: ...kaline water __ comes out j Alkaline pH level 1 Alkaline pH level 2 Acidic water comes out Alkaline pH level 3 Alkaline pH level 4 3 When you push the alkaline water button during the purified water m...

Страница 16: ...or will vary according to the chosen pH level 1 09 QG6 Acidic water comes out 3 Whenyou push the acidic water button during the purified water mode The unit gives the Acidic strength level 1 voice not...

Страница 17: ...the operation knob clockwise to have a water inflow into the unit After pushed the purified water button if operation knob does not open ON within 8 seconds it will return to alkaline water standby m...

Страница 18: ...iconontheLCDScreen The melody function works only in the acidic water outlet mode A voice guide works even in case the melody sound is off ALKAUNE WATER PURIFIED WATER ACIDIIC WATER MELODY ALKALINE WA...

Страница 19: ...when you use ON 2 Shut o the water inflow into the unit Turn o the Operation Knob 3 Open the filter cover as shown in the below pictures Push the filter cover lockpartinthe arrowdirection 4 Disconnect...

Страница 20: ...switch and have water inflow into the unit for 2 3 minutes turning on the operation knob repeat it 2 or 3 times Afterreplacingwith a newfilter initialoutletwatermaybe dark coforedSuch a dark coloris...

Страница 21: ...ality and unit operation condition 8 Always use the producer s authentically approved filter for the unit The following conditions are the result of NOT using an authentic approved filter The unit has...

Страница 22: ...n Block Step 2 Sediment b b b b PPSediments filters big suspended particulates rust and dirt etc from the source water CarbonBlock is composed of two types of high performance cconut shell based NSF c...

Страница 23: ...xed solution color with the colorimetric analysis chart provided Obtainable pH value can be vary according to source water quality water inflow pressure and water temperature pH resgent mixed solution...

Страница 24: ...suddenly cut off during operation Too high TDS total dissolved solids Itis the apparatus automaticfunctionto protectthe unitmechanismfroma possibleexcessiveelectriccurrent The unitwill automaticallyr...

Страница 25: ...d water The water storage bottle or receptacle is contaminated Contamination is added into the bottle when collecting output water from the unit Filter is seriously polluted Check cleanliness of a wat...

Страница 26: ...s Tap water supply by turning on off operation Knob Electrolysis Electrolysis Method Continuous electrolysis Electrolysis Levels 1 4 Alkaline Purified 1 2 Acidic Output Rate Max 4 Liters per minute al...

Страница 27: ...arranty sheet for repair free of charge Warranty Regulations 1 Warranty term 12 months from purchase date 2 Exceptions to warranty Expiration of warranty terns Defect caused by a natual disater such a...

Страница 28: ...unit Producer Alkamedi Co Ltd Address Megavalley 601 602 ho 268 Hagui ro Dongan gu Anyang si Gyeonggi do 14056 Rep of Korea Ver 1 1706 Marketed by SUZUION TECHNOLOGIES PVT LTD Address GRM Building 8 5...