background image

III

EXPLODED 

VIEW

A

DIGITAL 

WATER 

IONIZER

NO

DWG NO

DESCRIPTION

DESCRIPTION(KO)

Q

RERK

1

20-BA-001

BASE

lo|

1

2

00-BA-100

DIN 

BALL VN

1

3

20-BA-100

FILTER  OUTLET

1

4

00-BAD-200

FLOW METER

1

5

00-BA-009

ELECTROLYZER  INLET  PIPE

1

6

20-BA-101

INLET 

PIPE

1

7

00-ECB-104

ELECTROLYZERINLET

1

8

20-BA-002

FILTER  MANIFOLD

1

9

21-BA-004

CERAMIC  VALVE  ASSY(A-1)

1

10

20-BA-012

CONTROLHANDLE

1

11

00-BA-014

HANDLE  CLIP

1

12

00-BA-012

FITTING  1/4"(AEUO4O4)

1

13

00-BA-006

CORD  FIXATION

1

14

00-BA-105

AC  CORD  BUSHING

1

15

00-BA-101

DRAIN NIPPLE

1

16

20-BA-005

N FlTION

1

17

00-TR-12050

POWER TNS

_^

1

18

00-ECM-100

ELECTROLYZER 5P

1

19

00-EC-200

FLOW  DIVERTER  S/A

1

20

20-BK-001

BACK  CASE

1

21

20-PB-001

PBA  BASE  PTE

PCB 

CH

1

22

20-PB-

MAIN  PBA

PCB

1

23

20-PB-100

HEAT  SINKING  PLANE

1

24

22-FR01

FRONT  CASE

1

25

2O-FRM-001

MOOD 

P CASE

1

26

20-SW01

SCOVER

1

27

00-SW01

POWER  SWITCH

1

28

30-SW-001

MUSE  HOLDER

1

29

00-BK01

SPEAKER

^-I

1

30

00-EC-003

HOSE  CLAMP(A)

2

31

00-EC04

ACDIC  WATER  HOSE

1

32

00-EC-104

ELECTROLYZER OUTLET

1

33

20-EC-100

OUTLET EXTENSION

1

20-SP-001

POCKET

1

35

20-ZB-100

OUTLET CAP

1

36

00-SP-001

FIX.  CLIP

3

37

30-ZB-103

FLEXIBLE OUTLET

1

38

30-FR-003

SCREEN  BCKET

1

39

20-FR04

2000  LCD

LCD 

1

40

22-FR-002

LCD  FRONT  PANEL

1

41

41-FR-007

BUTTON  PCB

-PCB

1

42

40-FR-007

GASKET

4

43

20-FR-003

DECO.BAR

1

22-FR02

PET  FILM

1

45

FB2(X)

CARBON  BLOCK  FILTER

1

46

20-SP-002

FILTER  COVER

1

47

20-PK-005

POCKET  COVER

1

Содержание AMS 2200S

Страница 1: ...DIGITAL WATER IONIZER...

Страница 2: ...S PACKAGECONTENTS APPEARANCE ANDFUNCTIONAL STRUCTURE INSTALLATION HOWTOOPERATE FILTER REPLACEMENT FILTER COMPOSITION pH VALUETEST TROUBLESHOOTING UNITSPECIFICATIONS EXPLODED VIEW UNITCONVERSION TABLES...

Страница 3: ...this warranty sheet for repair free of charge Warranty Regulations 1 Warranty term 12 months from purchase date 2 Exceptions to warranty B Expiration of warranty terns Defect caused by a natual disat...

Страница 4: ...0 18 U S gal 0 21 U S gal 0 23 U S gal 0 26 U S gal 0 29 U S gal 0 31 U S gal 0 34 U S gal 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 U S gal U S gal U S gal U S gal U S gal U S gal U S gal U S gal U S gal...

Страница 5: ...they have been given supervision or instruction Children must be supervised notto play with this appliance For better drinking Always discard the initial dispensed water as a precaution This will ens...

Страница 6: ...ating Do not use a damaged plug or unstable wall outlet If the supplied cord is damaged it must be replaced by the manufacturer IfBIfl its service agent or qualified persons Please refer to this condi...

Страница 7: ...ROLYZER5P 1 19 00 EC 200 FLOW DIVERTER S A 1 20 20 BK 001 BACK CASE 1 21 20 PB 001 PBA BASE PTE PCB CH 1 22 20 PB MAIN PBA PCB 1 23 20 PB 100 HEAT SINKING PLANE 1 24 22 FR01 FRONT CASE 1 25 2O FRM 001...

Страница 8: ...EXPLODED VIEW D IGITAL WATER ID N IZER ES 11...

Страница 9: ...ater W municipal water etc Let the unit have water input and output for 2 3 minutes before first operation of the unit after installation Never allow hot water input into the unit n This may cause sev...

Страница 10: ...e Do not use an Aluminum weak against alkaline liquid copper weak against acid or other metallic receptacle to store ionized water 1 Glass or ceramic containers are recommended Do not drink ionized or...

Страница 11: ...ttons Unit Operation Means Tap water supply by turning on off Operation Knob Electrolysis Device Electrolysis Method Continuous electrolysis Electrolysis Strength 1 4 Level Output Rate Max 3 Liters pe...

Страница 12: ...e select pH level 1 2 i e lower pH strength At first no smell but smell from the output water in about 1 hour after collecting ionized water The water storage bottle or receptacle is contaminated Cont...

Страница 13: ...ter Paper One touch Drain water outlet Fitting Safety Key hose holder 1 4 Source Water Inlet Hose Screws and holders Fuse Faucet Water Diverter Water Outlet Dispenser Cover AMS 2200 only AMS 22008 wil...

Страница 14: ...Function Indicator 4 Operation Knob Water Supply Control Valve 5 Touch Buttons O O O 6 Main Power Switch 7 Fuse Holder 8 Filter Cover g Speaker 10 Holes for Wall Mount 11 Rear Side 12 Label i 1 Gt 13...

Страница 15: ...cut off dun ngoperation Too high TDS total dissolved solids In case of well water or bore water used It is the apparatus automatic function to protect the unit mechanism from a possible excessive elec...

Страница 16: ...h pH value by comparing the mixed solution color mixed solution analysis chart with the colorimetric analysis chart provided Obtainable pH value can be vary according to source water quality water inf...

Страница 17: ...hoice Indicator Indicates the choice of purified water 10 Alkaline Water Choice Indicator Indicates the choice of alkaline water 11 Water Inflow Rate Indicator Optimum flow rate 2 0 2 5 liters per min...

Страница 18: ...location of the wall after slightly pasting the guide paper with water Drill holes into the wall on the wall stud position as shown in the guide paper and insert the screw holders Screw down the studs...

Страница 19: ...s cyst bacteria THMs VOCs taste odour and other contaminants in the source water This is composed of coconut shell based NSF certified activated carbon and silver impregnated carbon to enhance the ant...

Страница 20: ...with trapped contaminants can encourage bacterial growth Ensure regular usage to prevent this situation A filter life length can be changed according to the source water quality and unit operation co...

Страница 21: ...onnect the Source Water Inlet Hose to Water Inlet Port and Water Outlet to Drain Water Outlet Port Ensure that they fit tightly Connectthe SourceWaterInletHoseto the WaterInlet PortandfastenwiththeOne...

Страница 22: ...ose to Acidic Drain Water Outlet Portand cut the other end of the hoseto have sufficient length to reach the sink fc away acidic water or for connecting to an Drain Water Option Hose fixationholder ca...

Страница 23: ...ing with a new filter initial outlet water may be dark colored Such a dark color is caused by an outflow of active carbon fines from the new filter The carbon fines fine size particles are not harmful...

Страница 24: ...ter Life The ic9n s tarts fl ickering when 3 of the full filter life remains available If When a filter life is over the filter life icon flickers and there is a voice guide please replace with a new...

Страница 25: ...ater Outlet Dispenser into Cap Hole Please make sure that 2 O Rings are tightly assembled I at groove not to make water leak F Please screw Flexible SUS Water Outlet Dispenser End clockwise into Outle...

Страница 26: ...and can be further extended intended direction It can be horizontally positioned horizontally horizontallyif required rotated O O O O o o o o O O O When the unit is not in regular use have the underne...

Страница 27: ...tion works only in the acidic water outlet mode A voice guide works even in case the melody sound is off Icondisappears Iconappears Filter Ufe ______________________________________ Therm Flow Ionize...

Страница 28: ...ice notice Purified water comes out from Flexible SUS Outlet Dispenser The screen backlight color will be green to indicate the purified water mode Purified water choice ind cation water flow dlrechon...

Страница 29: ...numerical form The optimum inflow rate is 2 0 5 liters min Adjust the water inflow rate by using the operation knob Inlet water Temperature Indcatlon Water inflow Ratelnd JN Rotate the operation knob...

Страница 30: ...e chosen pH level g I Alkaline water comes out Cb Alkaline pH level 2 Acidic water comes out I When you push the Alkaline Water button during the purified water mode The unit give the AlkalineStrength...

Страница 31: ...when you push the button repeatedly The screen backlight color will vary according to the chosen pH level Alkaline water comes out Acidic pH eve 2 Acidic pH level 1 When you push the Acidic water but...

Страница 32: ...unit Producer Alkamedi Co Ltd Address Megavalley 601 602 ho 268 Hagui ro Dongan gu Anyang si Gyeonggi do 14056 Rep of Korea Ver 1 1706 Marketed by SUZUION TECHNOLOGIES PVT LTD Address GRM Building 8 5...