4-1 The basic TX/RX commands
Check these commands if the unit does not transmit.
4-1-1 HBAUD command
abbrev HB default 1200 parameter 1200/9600
example HBAUD 9600, HB1200
This is to determine the speed of transmitted data. If 1200 is set, it enables AFSK at 1200bps. At
this position the modulated signal is output from the T1200(29
th
pin) on the gate-array but no
output from the T9600 (35
th
pin). When 9600 is set, GMSK 9600 bps is enabled. T9600 (35
th
pin)
outputs the modulated signal, but NO output from the T1200(29
th
pin).
4-2-2 MYCALL command
abbrev,. MY default NOCALL parameter : up to 6 alphanumeric characters and SSID
example MY K6ANC-15
This is to set your callsign. Usually callsigns are less than 6 characters. You may add
a
SSID
(sub-station ID) to identify up to 16 different callsigns. To add a SSID, chose 0 to 15 preceded by
a “dash” [-]. If a SSID is not added, the callsign is processed as SSID [0]. Note that the EJ-41U
can transmit a signal without a callsign being entered (NO CALL). It is illegal to transmit a signal
without your identification, which is a callsign. PLEASE BE SURE TO SET YOUR CALLSIGN
FIRST. Also, if the same callsign is used by different stations (club-station callsign, home and
mobile set-up etc) you will encounter problems. Please use a SSID to differentiate the stations
and avoid problems.
4-1-3
XMITOK command
Abbrev. XM default ON parameter ON/OFF
Example XMITOK ON
This command enables PTT on/off. It should usually be set ON so that the packet will be
transmitted by the radio. If OFF is selected, the data would not be transmitted from the radio
even though data is output. Note that some difference may be found between conventional TNCs
and the EJ-41U on this setting.
Conventional TNC EJ-41U
* default is OFF. * default is ON.
* This parameter may be set automatically * Does not effect the MYCALL setting.
When MYCALL data is input.
4-1-4
Loop command
Abbrev. LOOP default: OFF parameter: ON/OFF
Example: LOOP ON