ALIGNER CCD2.0WIFI Скачать руководство пользователя страница 16

 

R0368

 

 

Cod. R0368 ‐ rev.1.0

(03/2020)

 

 

 

Page 14/14 

 

 

 

 

 

 

 
 

 

6.2

 

Horizontal/vertical angles 
reading testi 

The screen shows all the angle readings from the 
detectors divided into 5 blocks as follows:  

1‐

 

Alignment angles (see Figure 27); 

2‐

 

Convergence angles;  

3‐

 

Front level gauge and inclination  

4‐

 

Rear level gauge and inclination  

5‐

 

All levels with tolerance 

 

Figure 26 

 

 
Pressing  the  F5  key  displays  a  figure  with  a 
graphic  representation  of  the  meaning  of  the 
various angles (see Figure 21). 
Press F1 to exit.

 

Figure 27 

6.3

 

Encoder test on detectors 

 

The  screen  shows  the  readings  of  the  angular 
transducers (encoders) mounted on the detector 
pins. Turning the pin, it is possible to check that 
the value read corresponds to the rotation angle 
made (see Figure 28). 
The F5 key or grey key on the detector is used to 
reset the value indicated on the screen. 

 

ATTENTION:  The

  CCD2.0WiFi  models  have  the 

angular  transducer  (encoder)  mounted  only  on 
the rear right detector.

 

 
 

Figure 28 

 

6.4

 

Test Keypads 

 
The keypads of the 4 detectors are shown on the 
screen.  If  a  key  is  repeatedly  pressed,  the  one 
associated  on  the  screen  is  coloured  and  de‐
coloured alternately (see Figure 29). 
Press the F1 key on the PC keyboard to exit. 

 

Figure 29 

Содержание CCD2.0WIFI

Страница 1: ...R0368 Cod R0368 rev 1 0 03 2020 RESERVED TO AUTHORISED ASSISTANCE CENTRES WHEEL ALIGNMENT CCD2 0WIFI INSTALLATION AND ASSISTANCE MANUAL FOR TESTING AND CALIBRATIONS ...

Страница 2: ...regarding use and maintenance reserved for the end user are collected in the specific manual supplied with the machine or downloadable from the manufacturer s website Attention The CALIBRATION procedure is reserved for specialist technical assistance personnel for this reason access to them is password protected This password which must not be communicated to other persons is determined by the seq...

Страница 3: ... and Configuration 6 4 2 Initialisation of the front WIFI detectors 6 4 3 Configuration of the default SSID on the front WIFI detectors 7 4 4 Connection of sensors and internal devices of the detectors 8 5 CALIBRATION 9 5 1 Detectors calibration 9 6 TEST PROCEDURES 13 6 1 Reading the FW release communication test 13 6 2 Horizontal vertical angles reading testi 14 6 3 Encoder test on detectors 14 6...

Страница 4: ...l as illustrated in Figure 1 It is possible to fix the panels side by side or on two opposite walls as indicated in chap 2 Figure 1 Attention The frames suitable for attachment of the detector panels and those of the bracket panels optional STDA156 are different from each other To identify them easily consider that those for detectors have wide vertical strips while those for brackets have narrow ...

Страница 5: ...e power line should not be turned off during the night as the detectors must be recharged Figure 3 The batteries of the detectors are recharged when they are placed on the dedicated charging supports on the panel These supports carry 7 5V DC power supply Attention The poles must be correct check them when the detector is being charged If the poles are correct the battery is charged the green LED i...

Страница 6: ...the service PC to the connect Wi Fi network of the CCD2 0WiFi system which is generated by the Access Point supplied with the equipment to which the front detectors and the Tablet are also connected Figure 6 After the PC and the detectors have been switched on and connected to the connect network it is necessary to associate the detectors with the service PC following the procedure described below...

Страница 7: ...efault selection Note with the access point normally supplied Zyxel NBG6604 the search is carried out with broadcasting disabled When the WIFI association is completed the two icons in the lower right corner turn BLUE Instead if the association has not been carried out or the front detectors are off these icons are GREY Note the Bluetooth icons highlighted in RED indicate that the SW driver that m...

Страница 8: ...ectors so that they automatically connect to the different SSID it is necessary to proceed as follows Initialise the detectors with the Reset procedure see chap 4 2 Configure the chosen SSID on the detectors see chap 4 3 4 2 Initialisation of the front WIFI detectors To initially set up the CCD WIFI front detectors Reset WIFI procedure operations must be carried out manually using the appropriate ...

Страница 9: ...pper right part N B the detector must have been previously initialised see chap 4 2 and it can be recognised by its name CCD_WIFI V410 SX XXXXXXXXXXXX o CCD_WIFI V410 DX XXXXXXXXXXXX SX is the left detector DX is the right detector XXXXXXXXXXXX is the Mac address that differs for each detector Press the F4 key to confirm the configuration Wait for the detector configuration to complete and check t...

Страница 10: ...rger cable note this connector can be above JP101 or alongside JP102 depending on the board version JP101 Battery charger cable with serial cable also connected to JP300 Wiring code 18390 JP102 Battery Cable where provided Wiring cod 14144 label JP11 JP300 Enclosure data connection cable LOWER SIDE Wiring code 18390 JP303 Convergence CCD signal cable Wiring code 18286 JP304 CCD alignment signal ca...

Страница 11: ...alibration is performed only in case of replacement of transducers or following ascertained repetitive errors due to movements of transducers consequently to falls impacts etc Use the following calibration systems according to the models supplied 1 STDA14 calibration system Figure 15 2 STDA14T transportable calibration system Figure 16 Legend Figure 15 Figure 16 A Detector fixing knobs B Spirit le...

Страница 12: ...ss through the following password F8 F7 F6 F8 Figure 18 Select using the F3 F2 keys the Detector Calibration option and confirm with the F4 key Figure 19 If required press F3 to be able to enter the serial numbers of the detectors so that they can eventually be mentioned in the print report If necessary also enter the serial number of the tool and the name of the operator Continue by pressing F4 F...

Страница 13: ...and Level Gauge angles are calibrated AFR ARR LFR LRR In phases 5 and 6 the front left and front right detectors are mounted and the front convergence and inclination angles are calibrated TFL TFR CFL CFR In phases 7 and 8 the rear left and rear right detectors are mounted and the rear convergence and inclination angles are calibrated TRL TRR CRL CRR AFL Alignment Front Left AFR Alignment Front Ri...

Страница 14: ...calibration phase 3 Calibration phases already acquired 4 Angle calibrated in the current phase with the relative tolerance 5 Currently read angular value 6 Graphical description of the positioning of the detectors on the stand 7 Keys used to perform the calibration phase F5 or the central key on the detector it is shown and flashes when it can be pressed Press F5 to store the values and then F4 t...

Страница 15: ...the Test Application option the Figure 24 page appears Figure 24 6 1 Reading the FW release communication test The screen shows all the FW versions read by the detectors With this test it is possible to verify the communication between the rear and front sensors and between the front sensors and the enclosure Press F1 to exit Figure 25 Note The detectors must be equipped with CPU 20624 and 20177 w...

Страница 16: ... 6 3 Encoder test on detectors The screen shows the readings of the angular transducers encoders mounted on the detector pins Turning the pin it is possible to check that the value read corresponds to the rotation angle made see Figure 28 The F5 key or grey key on the detector is used to reset the value indicated on the screen ATTENTION The CCD2 0WiFi models have the angular transducer encoder mou...

Отзывы: