Lightening rod

Communicate  

arrester

Video arrester

Power arrester

45

°

 conical 

envelope

The resistance of 

earthing conductor 

 must be less than 4 Ω. 

 

The camera should be 

within a 45

°

 envelope 

under the lightening rod. 

Steel jacket

Lightning & Surge Protection

Wire gauge standards

Bare Wire Gauge(mm)

American Wire Gauge 

(AWG)

Cross-sectional Area of 

Bare Wire (mm

2

)

0.750

21

0.4417

0.800

20

0.5027

0.900

19

0.6362

1.000

18

0.7854

1.250

16

1.2266

1.500

15

1.7663

2.000

12

3.1420

2.500

4.9080

3.000

7.0683

12 Vdc Wire Gauge and Transmission Distance

The following table shows the recommended maximum distance adopted for the different wire sizes when 
the 12 Vdc voltage loss is less than 15%. For example, for a device with the rating power of  
20 VA which is installed 77 feet (22 m) from the transformer, the minimum wire gauge required is 1.0000 
mm (18 gauge). 

Power (VA)

Wire size mm (gauge)

0.800 (20)

1.000 (18)

1.250 (16)

2.000 (12)

10

97 (28)

153 (44)

234 (67)

617 (176)

20

49 (14)

77 (22)

117 (33)

308 (88)

24

41 (12)

64 (18)

98 (28)

257 (73)

30

32 (9)

51 (15)

78 (22)

206 (59)

40

24 (7)

38 (11)

59 (17)

154 (44)

48

20 (6)

32 (9)

49 (14)

128 (37)

50

19 (6)

31 (9)

47 (13)

123 (35)

60

16 (5)

26 (7)

39 (11)

103 (29)

70

14 (4)

22 (6)

33 (10)

88 (25)

80

12 (3)

19 (5)

29 (8)

77 (22)

90

10.8 (3.1)

17 (5)

26 (7)

69 (20)

100

9.7 (2.8)

15 (4)

23 (7)

62 (18)

110

8.9 (2.5)

14 (4)

21 (6)

56 (16)

120

8.1 (2.3)

13 (4)

20 (6)

51 (15)

130

7.5 (2.1)

11.8 (3.4)

18 (5)

47 (14)

140

7 (2)

11 (3.1)

17 (5)

44 (13)

150

6.5 (1.9)

10.2 (2.9)

16 (4)

41 (12)

160

6.1 (1.7)

9.6 (2.7)

15 (4)

39 (11)

170

5.7 (1.6)

9 (2.6)

14 (4)

36 (10)

180

5.4 (1.5)

8.5 (2.4)

13 (4)

34 (10)