8
www.observint.com
© 2018 Observint Technologies. All rights reserved.
Network
Network Storage
Built-in microSD / SDHC / SDXC card slot (up to 128GB) local storage and NAS (NFS, SMB/CIFS),
ANR
Alarm Trigger
Motion detection, tampering alarm, HDD full, HDD error, network disconnected,
IP address conflicted, illegal login, alarm input
Protocols
TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, PPPoE, NTP, UPnP, SMTP, SNMP,
IGMP, 802.1X, QoS, IPv6, Bonjour
General Function
One-key recovery, Anti-Flicker, three streams, heartbeat, mirror,
password protection, video mask, watermark, IP address filtering
System Compatibility
ONVIF (Profile S, Profile G), ISAPI
User / Host
Up to 32 users, 3 levels: Administrator, Operator and User
VMS
Alibi CMS (ACMS)
Web browser
Microsoft Internet Explorer 8 or later
Interface
Audio
1 input (line in), 1 output, mono sound
Communication
Interface
1 RJ45 10M / 100M Ethernet interface
Alarm
1 input, 1 output (max. 12 Vdc, 30 mA)
Video output
1 Vp-p composite output (75 Ω / BNC)
On-board storage
Built-in Micro SD / SDHC / SDXC slot, up to 128GB
Reset Button
Yes
Audio
Environment Noise
Filtering
Supported
Audio bit rates
64 Kbps (G.711) / 16 Kbps (G.722.1) / 16K bps (G.726) / 32~192 Kbps (MP2L2)
Smart features
Behavior Analysis
Line crossing detection, Intrusion detection, Unattended baggage detection,
Object removal detection
Line Crossing Detection
Cross a pre-defined virtual line
Intrusion Detection
Enter and loiter in a pre-defined virtual region
Unattended Baggage
Objects left over in the pre-defined region such as the baggage, purse, dangerous materials
Object Removal
Objects removed from the pre-defined region, such as the exhibits on display.
Recognition
Face Detection
General
Operating Conditions
-22 °F ~ 140 °F (-30 °C ~ 60 °C)
Humidity 95% or less (non-condensing)
Power Supply
12 Vdc ± 25%, PoE (802.3af Class3)
Power Consumption
12 VDC, 0.75 A, max. 9.5W
PoE (802.3at, 36V ~ 57V), 0.3 A ~ 0.1 A, max. 11 W
Impact protection
IK10
Weather Proof
IP67
IR Range (Frequency)
Up to 98 ft (30 m), (850 nm)
Dimensions
Φ 6.04” × 5.24” (Φ 153.4 × 133.1 mm)
Weight
Camera: (2.84 lb (1287 g)
Options
ALI-AF11 Flange Adapter
Wire gauge standards
Bare Wire Gauge(mm)
American Wire Gauge
(AWG)
Cross-sectional Area of
Bare Wire (mm
2
)
0.750
21
0.4417
0.800
20
0.5027
0.900
19
0.6362
1.000
18
0.7854
1.250
16
1.2266
1.500
15
1.7663
2.000
12
3.1420
2.500
4.9080
3.000
7.0683
12 Vdc Wire Gauge and Transmission Distance
The following table shows the recommended maximum distance adopted for the different wire sizes
when the 12 Vdc voltage loss is less than 15%. For example, for a device with the rating power of
20 VA which is installed 77 feet (22 m) from the transformer, the minimum wire gauge required is
1.0000 mm (18 gauge).
Power (VA)
Wire size mm (gauge)
0.800 (20)
1.000 (18)
1.250 (16)
2.000 (12)
10
97 (28)
153 (44)
234 (67)
617 (176)
20
49 (14)
77 (22)
117 (33)
308 (88)
24
41 (12)
64 (18)
98 (28)
257 (73)
30
32 (9)
51 (15)
78 (22)
206 (59)
40
24 (7)
38 (11)
59 (17)
154 (44)
48
20 (6)
32 (9)
49 (14)
128 (37)
50
19 (6)
31 (9)
47 (13)
123 (35)
60
16 (5)
26 (7)
39 (11)
103 (29)
70
14 (4)
22 (6)
33 (10)
88 (25)
80
12 (3)
19 (5)
29 (8)
77 (22)
90
10.8 (3.1)
17 (5)
26 (7)
69 (20)
100
9.7 (2.8)
15 (4)
23 (7)
62 (18)
110
8.9 (2.5)
14 (4)
21 (6)
56 (16)
120
8.1 (2.3)
13 (4)
20 (6)
51 (15)
130
7.5 (2.1)
11.8 (3.4)
18 (5)
47 (14)
140
7 (2)
11 (3.1)
17 (5)
44 (13)
150
6.5 (1.9)
10.2 (2.9)
16 (4)
41 (12)
160
6.1 (1.7)
9.6 (2.7)
15 (4)
39 (11)
170
5.7 (1.6)
9 (2.6)
14 (4)
36 (10)
180
5.4 (1.5)
8.5 (2.4)
13 (4)
34 (10)