TVS 2000V Lightning and Surge Protection Feature Guidelines

This product includes TVS plate lightning protection technology to prevent damage caused by a pulse 
signal that is below 3000 watts from sources such as lighting, surging, etc. Protection measures must be 
taken to ensure electrical safety.

• 

The distance between signal transmission line and high-voltage equipment or high-voltage cable 
is at least 50 m.

• 

Outdoor wiring should better be along the eaves as much as possible.

• 

In the open field, wiring should be buried underground in sealed steel pipe with one-point 
grounding. Overhead routing method is not acceptable.

• 

In regions with thunderstorms or where high induction voltage are present (such as high-voltage 
transformer substation), high power lightning protection apparatus and lightning conductor are 
necessary. 

• 

The design for installation and wiring with lightning protection and grounding should be combined 
with the lightning protection consideration of the building, and conform to the relevant national 
and industry standards.

• 

The system should ensure equipotential grounding. Grounding equipment must satisfy both system 
anti-jamming and electric safety. It must not allow short circuit and open circuit with the zero 
conductor of strong grid. When the system is singularly ground, the resistance must less than 4 Ω 
and the cross-sectional area of the grounding cable must be no less than 25 mm

2

. For grounding 

instructions, refer to local electrical codes and this manual. 

Lightening rod

Communicate  

arrester

Video arrester

Power arrester

45

°

 conical 

envelope

The resistance of 

earthing conductor 

 must be less than 4 Ω. 

 

The camera should be 

within a 45

°

 envelope 

under the lightening rod. 

Steel jacket

Lightning & Surge Protection

Wire gauge standards

Bare Wire Gauge(mm)

American Wire Gauge 

(AWG)

Cross-sectional Area of 

Bare Wire (mm

2

)

0.750

21

0.4417

0.800

20

0.5027

0.900

19

0.6362

1.000

18

0.7854

1.250

16

1.2266

1.500

15

1.7663

2.000

12

3.1420

2.500

4.9080

3.000

7.0683

12 Vdc Wire Gauge and Transmission Distance

The following table shows the recommended maximum distance adopted for the different wire sizes when 
the 12 Vdc voltage loss is less than 15%. For example, for a device with the rating power of  
20 VA which is installed 77 feet (22 m) from the transformer, the minimum wire gauge required is 1.0000 
mm (18 gauge). 

Power (VA)

Wire size mm (gauge)

0.800 (20)

1.000 (18)

1.250 (16)

2.000 (12)

10

97 (28)

153 (44)

234 (67)

617 (176)

20

49 (14)

77 (22)

117 (33)

308 (88)

24

41 (12)

64 (18)

98 (28)

257 (73)

30

32 (9)

51 (15)

78 (22)

206 (59)

40

24 (7)

38 (11)

59 (17)

154 (44)

48

20 (6)

32 (9)

49 (14)

128 (37)

50

19 (6)

31 (9)

47 (13)

123 (35)

60

16 (5)

26 (7)

39 (11)

103 (29)

70

14 (4)

22 (6)

33 (10)

88 (25)

80

12 (3)

19 (5)

29 (8)

77 (22)

90

10.8 (3.1)

17 (5)

26 (7)

69 (20)

100

9.7 (2.8)

15 (4)

23 (7)

62 (18)

110

8.9 (2.5)

14 (4)

21 (6)

56 (16)

120

8.1 (2.3)

13 (4)

20 (6)

51 (15)

130

7.5 (2.1)

11.8 (3.4)

18 (5)

47 (14)

140

7 (2)

11 (3.1)

17 (5)

44 (13)

150

6.5 (1.9)

10.2 (2.9)

16 (4)

41 (12)

160

6.1 (1.7)

9.6 (2.7)

15 (4)

39 (11)

170

5.7 (1.6)

9 (2.6)

14 (4)

36 (10)

180

5.4 (1.5)

8.5 (2.4)

13 (4)

34 (10)