Fig. 9
Fig. 10
6) If necessary, support the pipe with FIP pipe clip model ZIKM and DSM distance
plates.
The VEE valve can be equipped with a simple locking device by inserting a lock
to protect the system against tampering (fig. 12). The valve body and hub are,
in fact, set to house a lockable plate on the valve body using two self-threading
screws (see SHE accessories) (fig. 11),
WARNINGS
- If volatile liquid such as Hydrogen Peroxide (H2O2) or Sodium Hypochlorite
(NaCIO) are used, for safety reasons we recommend you contact the service cen-
tre. These liquids, upon vaporising, could create hazardous over pressures in the
area between the body and ball.
- Always avoid sudden closing manoeuvres and protect the valve from accidental
manoeuvres.
Fig. 11
Fig. 12