Algo 8036 Скачать руководство пользователя страница 48

  

 

 

                             

8036 SIP Multimedia Intercom (FW 1.5.1)

 

Document 90-00081 

Algo Communication Products Ltd 

(604) 454-3792 

2017-05-11 

4500 Beedie St Burnaby BC Canada V5J 5L2 

[email protected]

 

Page 48

 

 

www.algosolutions.com

  

 

 

   

 

known as IEEE 802.1p and defines the Generic Attribute Registration 

 

Protocol. 
 

VLAN ID 

 
 

Specifies the VLAN to which the Ethernet frame belongs. A 12-bit 

 

field specifying the VLAN to which the Ethernet frame belongs. The 

 

hexadecimal values of 0x000 and 0xFFF are reserved. All other 

 

values may be used as VLAN identifiers, allowing up to 4094 VLANs. 

 

The reserved value 0x000 indicates that the frame does not belong to 

 

any VLAN; in this case, the 802.1Q tag specifies only a priority and is 

 

referred to as a priority tag. On bridges, VLAN 1 (the default VLAN 

 

ID) is often reserved for a management VLAN; this is vendor specific. 

 

VLAN Priority 

 
 

Sets the frame priority level. Otherwise known as Priority Code Point 

 

(PCP), VLAN Priority is a 3-bit field which refers to the IEEE 802.1p 

 

priority. It indicates the frame priority level. Values are from 0 

 

(lowest) to 7 (highest). 

  
 

Differentiated Services (6-bit DSCP value) 

 

 Provides quality of service if the DSCP protocol is supported on your 
network. Can be specified independently for SIP control packets 
 versus RTP audio packets. 

 

 

 

Содержание 8036

Страница 1: ... Communication Products Ltd 604 454 3792 2017 05 11 4500 Beedie St Burnaby BC Canada V5J 5L2 support algosolutions com Page 1 www algosolutions com 8036 SIP Multimedia Intercom FW Version 1 5 1 Installation Configuration Order Codes 8036 SIP Multimedia Intercom ...

Страница 2: ...OUNTING INTO OTHER MATERIALS OR OUTDOORS 14 SURFACE MOUNTING 15 MOUNTING HEIGHT 17 POE NETWORK CONNECTION 18 WEB INTERFACE 19 ACCESSING THE CONTROL PANEL 19 FINDING THE IP ADDRESS 19 APPLICATION DEVELOPMENT 21 OVERVIEW 21 CREATING USER INTERFACE SCREENS 21 CUSTOM GRAPHIC SCREENS 22 DIRECTORY ADDRESSBOOK LISTINGS 22 UPLOADING USER CONTENT 22 RESET 23 WEB INTERFACE LOGIN 24 STATUS 24 STATUS TAB VIDE...

Страница 3: ...EAM 32 MAXIMUM BROWSER SESSIONS 32 SESSION PASSCODE 32 WEB VIDEO RESOLUTION 32 BASIC SETTINGS TAB DOOR CONTROL 33 NUMBER OF NETWORK DOOR CONTROLLERS 34 DOOR UNLOCK TONE 34 ADDRESS 34 PASSWORD 34 MOMENTARY OPEN CODE 34 DURATION 34 LATCH OPEN CODE 34 LATCH CLOSED CODE 35 ACCESS CODE 35 USER INTERFACE TAB GENERAL 36 NUMBER OF ACTIVE PAGES 36 HOME PAGE 37 DEFAULT LCD BRIGHTNESS 37 DOOR UNLOCK MESSAGE ...

Страница 4: ...ANAGER 45 ADVANCED SETTINGS TAB NETWORK 47 PROTOCOL 47 VLAN MODE 47 VLAN ID 48 VLAN PRIORITY 48 DIFFERENTIATED SERVICES 6 BIT DSCP VALUE 48 ADVANCED SETTINGS TAB ADMIN 49 PASSWORD 49 CONFIRMATION 49 DEVICE NAME HOSTNAME 50 INTRODUCTION SECTION ON STATUS PAGE 50 WEB INTERFACE SESSION TIMEOUT 50 PLAY TONE AT STARTUP 50 LOG LEVEL 50 LOG METHOD 50 LOG SERVER 50 WEB INTERFACE PROTOCOL 50 FORCE STRONG P...

Страница 5: ...URE 59 BACKUP SERVER 1 59 BACKUP SERVER 2 59 POLLING INTERVALS SECONDS 59 POLL ACTIVE SERVER 59 AUTOMATIC FAILBACK 60 POLLING METHOD 60 SYSTEM TAB MAINTENANCE 61 DOWNLOAD CONFIGURATION FILE 61 RESTORE CONFIGURATION FILE 61 RESTORE CONFIGURATION TO DEFAULTS 61 DOWNLOAD UI BACKUP SIP FILE 61 RESTORE FROM UI BACKUP ZIP FILE 62 RESTORE ALL UI SETTINGS AND FILE TO DEFAULTS 62 REBOOT THE DEVICE 62 METHO...

Страница 6: ...tation par Ethernet des câbles de catégorie 5 et 6 joignent un commutateur réseau à alimentation par Ethernet homologué IEEE 802 3af Le produit est conçu pour être installé à l intérieur ou dans une zone adjacente à un édifice selon le manuel d installation des mesures de sécurité additionnelles s avèrent alors nécessaires Tout le câblage rattaché au produit doit se trouver dans le même édifice Si...

Страница 7: ...ne Cat 6 Verbindung zu einer IEEE 802 3af konformen Ethernet Netzwerkweiche Das Produkt wurde konzipiert für die Installation innerhalb eines Gebäudes oder außerhalb eines Gebäudes Bei der Anwendung außerhalb eines Gebäudes müssen zusätzliche Schutzmaßnahmen gemäß der Gebrauchsanweisung durchgeführt werden Alle Kabelverbindungen zum Produkt müssen im selben Gebäude bestehen Wenn das Produkt jensei...

Страница 8: ... outdoor locations and may be subjected to spray or weather provided the rear wiring cavity is properly sealed to prevent water ingress Gaskets included with the 8036 SIP Multimedia Intercom may be effective against water ingress on some but not all surfaces in which case additional protective measures must be taken such as a perimeter sealant CAT5 or CAT6 connection wiring to an IEEE 802 3af comp...

Страница 9: ...onfigurations the product is designed for outdoor or public access locations to provide enhanced communication and support for guests and visitors The 8036 SIP Multimedia Intercom can be configured using central provisioning features or by accessing a web interface via browsers such as Google Chrome Firefox or Internet Explorer What is Included 8036 SIP Multimedia Intercom Network Cable Mounting G...

Страница 10: ...ultimedia Intercom FW 1 5 1 Document 90 00081 Algo Communication Products Ltd 604 454 3792 2017 05 11 4500 Beedie St Burnaby BC Canada V5J 5L2 support algosolutions com Page 10 www algosolutions com Product Tour ...

Страница 11: ... Firefox etc and login using the default password algo 3 Enter the IP address for the SIP server into the SIP Domain field under the BASIC SETTINGS SIP tab 4 Enter the page SIP Extension Authentication ID and Password Note The Authentication ID may also be called Username for some SIP servers and in some cases may be the same as the SIP extension 5 For basic testing create a UI test screen with a ...

Страница 12: ... Bezel for Installation The 8036 is shipped partially assembled and must be partially disassembled before it can be installed Remove the security screw behind the ALGO Logo Badge by first pressing on one side of the badge This will raise the other side so that it can be removed easily by hand A security bit Algo Security Tool is included with the 8036 that fits standard socket screwdrivers Use the...

Страница 13: ...that can be downloaded at www algosolutions com 8036mounting 2 Place the Drywall Bracket into wall and bend tabs around to the front of the drywall to hold in place 3 After connecting the Ethernet cable use the 8 x 1 5 Type A Pan Head screws to secure the 8036 housing to the Drywall Bracket 4 Replace the Front Bezel and keep the Algo Security Tool in a safe location 5 Replace the ALGO Logo Badge N...

Страница 14: ...e to the cut out edge A 8 anchor may be required not supplied for the wall material If outdoors 1 Create a drywall cut out per the template found at www algosolutions com 8036mounting A rubber Ethernet Cable boot is supplied to be placed over the network cable prior to terminating with a plug see PoE Network Connection on page 15 2 While the 8036 is designed to withstand rain it may be undesirable...

Страница 15: ... used on a wall surface where flush mounting is undesirable or not practical The bracket also may be good option when integrating the 8036 into stonework 1 Mount the Surface Mount Bracket using the 8 x 1 5 Type A Pan Head screws supplied For some wall materials 8 anchors may be required not included If outdoors a Ensure any opening in the wall is sealed or apply a silicon bead between the Surface ...

Страница 16: ...r to terminating with a plug see PoE Network Connection on page 15 c To prevent water from getting behind the 8036 place the Mounting Gasket on to the 8036 housing prior to mounting 2 After connecting the Ethernet cable use the 8 x 1 Type B Pan Head screws to secure the 8036 housing to the Surface Mount Bracket 3 Replace the Front Bezel and keep the Algo Security Tool in a safe location Replace th...

Страница 17: ...e 17 www algosolutions com Mounting Height The 8036 should be mounted at an appropriate height for your intended application The considerations are 1 Easy readability of the interface screens for users of different heights 2 Highest quality camera and video images For most applications a mounting height of approximately 55 inches 1 4 m from floor to center of display is recommended ...

Страница 18: ...036 location and then terminated with a male RJ45 plug If mounting outdoors slide the Ethernet Cable Boot onto the cable before installing the RJ45 plug After inserting the plug into the 8036 jack carefully position the boot into the jack cavity to prevent moisture or insects from getting inside If you don t have a PoE switch you ll need a PoE injector that installs between the 8036 and the networ...

Страница 19: ...cessing the Control Panel To access the 8036 Control Panel your first need to determine the 8036 s IP address and then enter this address into a browser Finding the IP Address After connecting the 8036 to a network PoE port the 8036 will attempt to obtain an IP address from the DHCP server and display this on the screen If this is the first time you are using the 8036 and no user interface has yet...

Страница 20: ... an IP address from the DHCP server it will default to the fixed IP address 192 168 1 111 The IP address may be discovered by downloading the Algo locator tool to find Algo devices on your network www algosolutions com locator Enter the IP address eg 192 168 1 111 into a browser such as Google Chrome Firefox or Internet Explorer other than IE9 The web interface should be visible and the default pa...

Страница 21: ... company logo and graphics On it you can have buttons that make calls or that lead to various information or directory pages Example 8036 Custom Graphics Screen using 3x3 Full Button layout with three active buttons You can set all of this up using the 8036 Control Panel You ll also be able to back up all the configuration and user interface information to a PC for safekeeping Creating User Interf...

Страница 22: ...evelop custom interface screens you need to be able to create 640 x 480 pixel graphic files in the PNG GIF and JPEG formats Most graphics image editing programs such as Adobe Photoshop have this capability Within the graphics program you can create your own background and button graphics and then align the button graphics if used to the layouts you have chosen for your 8036 User Interface Photosho...

Страница 23: ...rd has been changed and then forgotten To do a soft reset 1 Disconnect the network cable from the 8036 and reconnect it again 2 Press the words Algo 8036 Firmware 1 5 1 within five seconds of their appearance in the top middle section of the screen see right A confirmation button will appear in the bottom middle area with the text description Press here to reset to factory default 3 Press this con...

Страница 24: ...ns com Web Interface Login The web interface requires a password which is algo by default This password can be changed using the Admin tab after logging in the first time Status The device s Status page will be available before and after log on The section can be used to check 8036 s SIP Registration status of the SIP extension Call Status Proxy Status and general MAC IP Netmask Date Time informat...

Страница 25: ...osolutions com Status Tab Video The video can be seen in the Status Video tab when the user is not logged in A separate video password can also be enabled to allow users to access the video but not the rest of the device settings This password can be set in Basic Settings Video tab Session Passcode field Video settings like brightness contrast are also available in the Basic Settings Video tab ...

Страница 26: ...m your telephone system administrator or hosted account provider After saving the settings see the Status tab to confirm the registration was successful Note Any time changes are made to settings in the Web Interface the Save key must be clicked to save the changes SIP Domain Proxy Server SIP Server Name or IP Address Extension Used to register the 8036 on the SIP Server Authentication ID May also...

Страница 27: ...0081 Algo Communication Products Ltd 604 454 3792 2017 05 11 4500 Beedie St Burnaby BC Canada V5J 5L2 support algosolutions com Page 27 www algosolutions com Authentication Password SIP password provided by the system administrator for the SIP extension ...

Страница 28: ... from 1 lowest to 10 highest Microphone Volume Select the microphone volume of the 8036 UI Volume The 8036 provides click sounds to provide users with audible feedback to assure them their key presses were registered You can adjust the sound volume for these feedback sounds from Mute to 10 loudest Answer Inbound Call Allows the doorphone to auto answer when it receives an inbound call Ensure the d...

Страница 29: ...be used to set a limit on how long the 8036 speaker will ring before timing out Ringback Tone Allow audible ringback tone to be played on the 8036 speaker until the call is answered G 722 Support Enable or disable the G 722 codec Maximum Call Duration Inbound Outbound Calls Select the maximum call length The call will be terminated once the maximum time is reached In the event that a call inadvert...

Страница 30: ...aby BC Canada V5J 5L2 support algosolutions com Page 30 www algosolutions com Basic Settings Tab Video Video Call Mode Select video call mode One way Video outgoing only The 8036 only sends video to the remote end eg a video phone It does not show any video on the 8036 itself Two way audio is still maintained in this configuration ...

Страница 31: ...supported packet type Single NAL Unit or Fragmentation Unit Type A FU A Quality Control Method Select method Constant Bitrate Allows modification of video parameters at constant bitrate Maximum Video Bandwidth QP Min and QP Max Constant Quality Allows PQ value default 28 modification given constant video quality Maximum Bandwidth Set a signal capacity for video content transmission QP Min Minimum ...

Страница 32: ...uency Choose the local powerline frequency For example 60 Hz in North America and 50 Hz in Europe Request Media Bandwidth Enable or disable as required by the far end phone SIP Video Stream This controls the resolution of the actual video stream sent by the 8036 Maximum Browser Sessions Allows for a limit to be set on the number of separate browser sessions that can be open simultaneously to show ...

Страница 33: ...p to four optional 8061 IP Relay Controllers to provide door control and security for up to four doors Each 8061 allows one door to open via a pre configured Door Access Keypad on the 8036 Each Door Access Keypad in turn allows multiple codes e g visitors employees etc to be configured for its associated door This application is useful in places like lobbies with up to four separate businesses uni...

Страница 34: ...1 IP Relay Controller Ensure that the two devices have matching passwords Default password is algo Note the Password is used solely to secure the link between the 8036 and the 8061 It is not the same as the Momentary Open Code Momentary Open Code Enter a 1 4 digit DTMF code default 6 that can be used to unlock the door for a brief period of time Leave this field blank to disable this feature Durat...

Страница 35: ...nter a 1 4 digit DTMF code that will lock the door again when it is latched open Leave this field blank to disable this feature Access Code Enter a 1 8 digit numeric code that can be used from the touch screen to unlock the door for a brief period of time Multiple codes can be entered by separating each code with a space comma or semicolon Typically used for employee tenant access Leave this field...

Страница 36: ... St Burnaby BC Canada V5J 5L2 support algosolutions com Page 36 www algosolutions com User Interface Tab General Number of Active Pages Select the number of configurable pages that will be created as part of the User Interface A new Page tab will appear in the tabs area These do not apply to Dial Keypads and Access Keypads ...

Страница 37: ...t Action below Timeout Action Select an action to take place after the User Interface Timeout period None allows the 8036 to indefinitely display the recently accessed page Go to Homepage returns the display screen to the start page Activate Slideshow loops through the images uploaded in the slideshow folder found in User Interface File Manager tab see page 45 for details Time between slides can b...

Страница 38: ... 8036 detects a visitor presence within 80cm directly from the screen cancelling the slideshow or screen dimming actions if enabled Action when Presence Detected If desired select an additional action like Call and extension to take place when a presence is detected Interval between Slides second Enter the time seconds between slides in the slideshow The range is 0 300 seconds 5 minutes Hangup But...

Страница 39: ...arance activation of specific buttons on the 8036 screen For instance to display 3 vertical buttons in the first column only the appropriate buttons should be activated Custom Graphics and Backgrounds Custom graphic screens with buttons that line up to the pre configured 8036 screen can be created using Photoshop templates available for download at www algosolutions com 8036templates For best appe...

Страница 40: ...0 Beedie St Burnaby BC Canada V5J 5L2 support algosolutions com Page 40 www algosolutions com Template Choose a display screen page type Button or Directory Description Enter a page description optional This description will be seen in the button Target Page drop down menus as well as the web interface tabs Example ...

Страница 41: ...area outside the button is pressed This option can be used when custom graphics display messages like Press anywhere to begin or Press anywhere to make a call Active buttons can still be configured on the screen or they can be disabled Back Button Adds a Back button to the lower left of the screen Clicking it will return the user to the previously displayed screen The Back button can be enabled or...

Страница 42: ...ge 42 www algosolutions com Action Specify whether you want the button to direct the user to a page keypad or Call an extension Action Call Destination Displayed when Action Type is set to Call Enter the extension to be dialed after the button is clicked Action Target Page Displayed when Action Type is set to Go to Page Select the page keypad to display after the button is clicked ...

Страница 43: ...ay directory entries see page 45 These entries can then be used by visitors to make calls to individuals listed in the file As an example here is the contents of a directory file with two fields one for name that will be displayed on the 8036 screen and one for telephone extension that the 8036 will dial Al Smith 1028 Bob Johnson 2156 John Jones 2345 Paul Phillips 1287 Terry Stevens 1256 Vicky Yor...

Страница 44: ...lutions com To create a tab delimited text file using Microsoft Excel 1 Open your spreadsheet document go to the Windows Office round button menu and choose Save As 2 Change the Save as type or Format field to read Text Tab delimited 3 Enter a name for the document and click Save The Addressbook entries should be sorted before upload to the 8036 as the device will not sort the entries in the file ...

Страница 45: ...o be available when configuring the device Tab delimited text files should be uploaded to the addressbook folder for directory entries page 43 Images can be uploaded to either the slides folder for slideshow displays page 37 or background folder for custom background screens page 39 For best appearance on the screen the image files should be 640 x 480 pixels 16 bit high color and in PNG JPEG or GI...

Страница 46: ...priate folder for the menu to appear and select upload or paste if you are copying the file from another folder Multiple files can be uploaded simultaneously by holding the Ctrl or Shift key when selecting the desired files in the file viewer window To delete rename cut copy an existing file right click on the file of choice The 8036 UI can also be backed up and restored to from a ZIP file in the ...

Страница 47: ...matically configure IP addresses for each 8036 SIP Multimedia Intercom on the network Alternatively the 8036 SIP Multimedia Intercom can be set to a static IP address VLAN Mode Enables or Disables VLAN Tagging VLAN Tagging is the networking standard that supports Virtual LANs VLANs on an Ethernet network The standard defines a system of VLAN tagging for Ethernet frames and the accompanying procedu...

Страница 48: ...lowing up to 4094 VLANs The reserved value 0x000 indicates that the frame does not belong to any VLAN in this case the 802 1Q tag specifies only a priority and is referred to as a priority tag On bridges VLAN 1 the default VLAN ID is often reserved for a management VLAN this is vendor specific VLAN Priority Sets the frame priority level Otherwise known as Priority Code Point PCP VLAN Priority is a...

Страница 49: ... log into the 8036 SIP Multimedia Intercom web interface You should change the default password algo in order to secure the device on the network If you have forgotten your password you will need to perform a reset using the Reset Button in order to restore the password as well as all other settings back to the original factory default conditions For additional password security see Force Strong P...

Страница 50: ...e has booted Log Level Use on the advice of Algo technical support only Log Method Allows the 8036 SIP Multimedia Intercom to write to external Syslog server if the option for external or both is selected Log Server If Network or Both is selected this is the address of the Syslog server on the network Web Interface Protocol HTTPS is always enabled on the device Use this setting to disable HTTP Whe...

Страница 51: ...nd all the configured Authentication Password s must be re entered in the Basic Settings SIP tab and any other locations where SIP extension have been configured to save the encrypted password s If the Realm is changed at a later time all the passwords will also need to be re entered again to save the passwords with the new encryption To obtain your SIP Realm information contact your SIP Server ad...

Страница 52: ... 1 2 3 4 The Intercom will attempt to use Timer Server 1 and work down the list if one or more of the time servers become unresponsive NTP Time Server Source When Use DHCP Option 42 is chosen if an NTP Server address is provided via the DHCP Option 42 that NTP Server will be used instead of the 4 mentioned above Alternatively Ignore DHCP Option 42 can be chosen to only use servers mentioned above ...

Страница 53: ...BC Canada V5J 5L2 support algosolutions com Page 53 www algosolutions com external NTP server the Sync with browser button can be used to temporarily set the time on the device Note this time value will be lost at power down or overwritten if NTP is currently active Time and date are used only for logging purposes and for the Scheduler ...

Страница 54: ...ed settings can be uploaded via Provisioning The User Interface cannot be auto provisioned at this time The device can be provisioned via the Auto mode where all three DHCP options Option 66 160 150 will be automatically checked for an active provisioning server just one of the three specified DHCP options or a Static Server In addition there are four different ways to download provisioning files ...

Страница 55: ...isioning server This checksum file is used to verify that the conf file is transferred correctly without error A tool such as can be found at the website address below may be used to generate this file http www fourmilab ch md5 The application doesn t need an installation To use the tool simply unzip and run the application md5 from a command prompt The proper md5 file will be generated in the sam...

Страница 56: ...enerating a generic configuration file 1 Rename file settings txt to algom MAC address conf e g algom0022EE020009 conf 2 File algom MAC address conf can now be uploaded on the Provisioning server The specific configuration file will only be downloaded by the 8036 SIP Multimedia Intercom with the MAC address specified in the configuration file name Since all the necessary settings can be included i...

Страница 57: ...mat may be uploaded into memory 1 GB to play for notification applications An existing file may also be modified by downloading the original via the links in the web interface making the desired changes and then uploading the new version with a different name Audio files must be in the following format WAV format 8kHz or 16kHz sampling rate 16 bit PCM or u law Mono A zip files containing one or mo...

Страница 58: ...com Advanced Settings Tab Advanced SIP Outbound Proxy IP address for outbound proxy A proxy server stands between a private network and the internet STUN Server IP address for STUN server if present Register Period seconds Maximum requested period of time where the 8036 SIP Multimedia Intercom will re register with the SIP server Default setting is 3600 seconds 1 hour Only change if instructed oth...

Страница 59: ...sive If Server Redundancy is selected the web page will expand as shown below Backup Server 1 If primary server is unreachable the 8036 SIP Multimedia Intercom will attempt to register with the backup servers If enabled the 8036 SIP Multimedia Intercom will always attempt to register with the highest priority server Backup Server 2 If backup server 1 is unreachable the 8036 SIP Multimedia Intercom...

Страница 60: ... 3792 2017 05 11 4500 Beedie St Burnaby BC Canada V5J 5L2 support algosolutions com Page 60 www algosolutions com Automatic Failback Reconnect with higher priority server once available even if backup connection is still fine Polling Method SIP message used to poll servers to monitor availability ...

Страница 61: ...nce Download Configuration File Save the device settings to a text file for backup or to setup a provisioning configuration file Restore Configuration File Restore settings from a backup file Restore Configuration to Defaults Resets all 8036 SIP Multimedia Intercom device settings to factory default values This will not restore the UI to defaults Download UI Backup SIP File Save the device UI sett...

Страница 62: ...lts Reboot the Device Reboots the device Method Specify whether the firmware files will be downloaded from the local computer or a remote URL Firmware Image Point to the firmware image provided by Algo MD5 Checksum Point to the checksum file provided by Algo Upgrade 8036 SIP Multimedia Intercom Firmware 1 From the top menu click on System then Maintenance 2 In the Upgrade section click on Choose F...

Страница 63: ... 604 454 3792 2017 05 11 4500 Beedie St Burnaby BC Canada V5J 5L2 support algosolutions com Page 63 www algosolutions com System System Log System log files are automatically created and assist with troubleshooting in the event the 8036 SIP Multimedia Intercom does not behave as expected ...

Страница 64: ...Sensor 6 0 x 6 0μm pixel size for low light performance 110dB dynamic range Image Memory Optional to 8 GBytes Touchscreen Optically bonded projected capacitance H7 hardness Presence Detection Area reflective 80cm range invisible light beam Speaker Wideband 8 W Microphones Dual beam forming wideband Hands free Full duplex capable reverting to hands free half duplex employing DSP echo cancellation a...

Страница 65: ... 1 Document 90 00081 Algo Communication Products Ltd 604 454 3792 2017 05 11 4500 Beedie St Burnaby BC Canada V5J 5L2 support algosolutions com Page 65 www algosolutions com Dimensions Height 10 3 4 27 3 cm Width 7 17 8 cm Depth 3 7 6 cm ...

Страница 66: ...l functionality when used with the optional Algo 8061 IP Relay Controller The 8061 serves as a bridge between the 8036 and peripheral hardware such as door strike As a door opening controller the 8061 can be located in a secure environment to prevent tampering of the public facing intercom The door control feature is activated by a command from the answering telephone keypad or entry of the door r...

Страница 67: ...door strike to the Normally Open Common NO C input pair or Common Normally Closer C NC input pair on the 8061 For more wiring information please visit www algosolutions com doorstrike Configuring the 8061 1 Find the IP address of the Algo 8061 using the Algo locator tool available from the Algo website www algosolutions com locator This tool displays all of the Algo devices available on the networ...

Страница 68: ...ge 68 www algosolutions com 5 Set the Door Control Link to Enabled 6 In the Door Control Password field set a password that will be used for configuring the intercom for door control Note this password down as you will be reusing it when configuring the 8036 with this device See section Basic Settings Tab Door Control page 33 for configuring the 8201 with the parameters from above ...

Страница 69: ...on Products Ltd 604 454 3792 2017 05 11 4500 Beedie St Burnaby BC Canada V5J 5L2 support algosolutions com Page 69 www algosolutions com Button Positioning Table The following table provides the location and sizing of standard button layouts for 8036 User Interface Screens ...

Страница 70: ...you ll find a link to a ZIP file containing multiple Photoshop files that provide guides for laying out User Interface screens for the 8036 Each file contains guides for placing buttons that corresponds to the 8036 s standard button configurations To use the files open up the Photoshop file that corresponds to the button configuration you want to use Then set Photoshop to snap to guides View Snap ...

Страница 71: ...15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment ...

Отзывы: