Photofinish OPTIc2.NET
Page 57
12.2 Class Mode
If you click on this icon the
heat list is shown separated by class names. Of course it
is necessary to input a class mode and to input bib and group with the evaluation (use <Bib
evaluation>
.
In the class mode it is possible to use the same bib numbers in each class. The class mode
is not available if you select <Track and field with anemometer> and <Track and field without
anemometer>.
Move the <Time Cursor> to the right position
Press the right mouse button for bib evaluation
Input the bib (ID-number)
Click on arrow next to bib number and select group
If you open the field bib evaluation always the
group is shown that you selected before. When
clicking on the arrow in the <Group name> field,
all possible groups are shown.
If you input a bib it shows automatically the right
class, if you have this bib only in one class.
If you have the same bib in different groups you
can see the bib in all groups here. This speeds
up the evaluation if you are not sure about the
group of the competitor.