background image

Manual 

Speaker System BANG2 

 

 

-7- 

2.3  Starting 

Before switching on, turn the controller MASTER (12) for total volume to MIN, then turn on the 
box with switch POWER (17). The switch glows during operation. In case it is blinking during 
operation with batteries, they are nearly empty and should be charged. 

In order to prevent damage to the batteries by total discharge, a discharge protection executes 
in time an automatic deactivation of the device. Due to the self-discharge, the batteries can 
also be discharged when the device is not in use for a longer period of time. Therefore, make 
sure to observe the note in chapter power supply. 

2.4  Connections for Timing 

The BANG2 can be integrated into the starting system with various devices of 

ALGE-TIMING

.  

Starting devices (connection by cable): 

  electronic starting device e-Start 

  Start Unit SU2 

  Start Unit SU3 

  start microphone SM8 with speech amplifier SV4/SM and headset HS3-2 

  push button 023-02 or 023-10 

  photocell PR1a 

False start devices (connection by cable): 

  electronic starting device e-Start W 

  radio push button WTN-PB 

  WTN 

  radio photocell PR1aW 

 

The starting signal is always triggered with a C0 pulse.  
Triggering a further C0 pulse within 5 seconds after starting pulse initiates the set false start 
signal.  
A further pulse on the set false start channel within these 5 seconds also initiates the set false 
start signal. 
 
Note: Every false start obligatory requires a start beforehand. This prevents accidentally trig-
gering a false start before the starting signal. 

 
Attention: 

All devices of the WTN series (e.g.  BANG2, e-Start W, WTN-PB, WTN) must be set to the 
same team! 

Содержание BANG2

Страница 1: ...Manual Version E20 01 24...

Страница 2: ...replaced immediately by an author ized electrician The device must only be connected to an electric supply that has been installed by an electrician according to IEC 60364 1 Never touch the mains plug...

Страница 3: ...of intended use com plies with the basic requirements of R TTE 1999 5 EC Telecommunication TC terminal device Applied harmonized standards EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 EMC EN 6006...

Страница 4: ...d level 10 2 7 4 False start sound 10 2 7 5 False start level 10 2 7 6 Setting of False Start Channel WTN recall channel 10 2 7 7 Setting of WTN Team WTN radio team 10 2 7 8 Delay Time Start Channel D...

Страница 5: ...nd confirmation button 6 tone control TREBLE 7 tone control BASS for mix signal 8 volume control for LINE IN 9 volume control for AUX 10 volume control for microphone at input MIC IN 16 11 charging st...

Страница 6: ...ANG2 without weather protection only indoor Protect it from dripping and splashing water high humidity and heat permitted temperature range 0 40 C The BANG2 can be freely placed or mounted onto the AL...

Страница 7: ...tem with various devices of ALGE TIMING Starting devices connection by cable electronic starting device e Start Start Unit SU2 Start Unit SU3 start microphone SM8 with speech amplifier SV4 SM and head...

Страница 8: ...icrophone and a stereo device with line output level microphone either via XLR or 6 3 mm jack plug to the symmetrically wired socket MIC IN 16 stereo device with line output to the Cinch sockets LINE...

Страница 9: ...should operate either with cable OR radio Mixing these connection types could cause feedbacks and other effects It is for instance not allowed to connect an e Start to a wireless false start system A...

Страница 10: ...hannel Set the timing channel for false start here Only a false start can be triggered on this channel Default setting is C4 2 7 7 Setting of WTN Team WTN radio team This setting adjusts the WTN team...

Страница 11: ...the menu with No without changes 2 7 11 Exit Settings Exit Confirming the menu item Exit results in displaying the status menu 2 8 Accessories ALGE TIMING offers the following accessories for BANG2 2...

Страница 12: ...peration time of BANG2 with battery operation depends on set volume and duration of active use Operating Time approx 3 to 4 hours at normal use 4 2 2 Charge Battery During mains connection of the acti...

Страница 13: ...8 tone control bass 15 dB 100 Hz treble 10 dB 10 kHz temperature range 0 40 C power supply via mains voltage 90 230 V 47 63 Hz 150 VA or internal lead gel batteries 2 12 V 3 Ah battery operating time...

Страница 14: ...Manual Speaker System BANG2 14...

Страница 15: ...Manual Speaker System BANG2 15...

Страница 16: ...Manual Speaker System BANG2 16 Subject to changes and misprints Copyright by ALGE TIMING GmbH Rotkreuzstr 39 6890 Lustenau Austria https www alge timing com...

Отзывы: