Electrical Service
The
ZIMMER
vaporizer is manufactured as an explosion proof
device suitable for hazardous locations. Do not separate the heat
exchanger to access the electrical enclosure –
separating the
enclosure will void warranty!
♦
When connecting the electrical service for the
ZIMMER
you will
need a circuit breaker appropriate for the application. See
Electrical Specifications in the Appendix.
♦
You will also need a disconnect switch located within sight of
the vaporizer (refer to Electrical Specification in Appendix).
♦
Select the appropriate size conductors based on the current
draw (refer to Electrical Specification in Appendix) and
conductor run distance (see reference charts below).
♦
Install metal terminal box to the ¾” MNPT seal-off to make the
wiring connections in accordance with the local electrical codes.
Ensure the terminal box is connected to seal-off before
vaporizer is mounted to wall.
Metal Terminal Box (3/4”) for 50kg/hr and Smaller models
Use a suitably certified metal terminal box for the area
classification, ATEX or IECEx certified - for Europe; or Class I,
Division 1, Group D (UL listed or equivalent) - for US and
Canada. Electrical components must be rated for 130
°
C
(266
°
F). (
ASDI P/N 80895
(CLASS I DIV 1) OR
80896
(ATEX
Ex d)
Metal Terminal Box (1-1/4”) for 100kg/hr and 150kg/hr models
Ex db IIA Gb or Ex eb IIA Gb, ATEX or IECEx certified - for
Europe; or Class I, Division 1, Group D (UL listed or equivalent)
- for US and Canada. Electrical components must be rated for
130
°
C (266
°
F). (
KILLARK P/N GESLT-4 or equivalent)
♦
Do not separate vaporizer sections to access the wiring. Use
conductor assembly provided.
♦
Connect the green conductor to ground. See appropriate wiring
schematic in Appendix based on your desired installation. Do
not pull on, twist, or bend the wires.
CAUTION________________________________________
When installing the metal terminal box, use an open-end wrench to
securely hold the factory provided seal-off to prevent twisting!
___________________________________________________