background image

Technical

 

Information

 

AGA

 

Approval

 

No:

   

AGA

 

8138

 

G

 

Note:

       

For

 

Use

 

outdoors

 

only

 

Conversion

 

to

 

natural

 

gas

 

only

 

to

 

be

 

done

 

by

 

authorized

 

person

 

The

 

maximum

 

cylinder

 

size

 

for

 

use

 

with

 

this

 

appliance

 

is

 

9kgs

 

The

 

thread

 

type

 

of

 

this

 

appliance

 

is

 

G1/4B

19.

 

Gas

 

Type

 

Universal

 

LP

 

Gas

 

&

 

Natural

 

Gas

 

Universal

 

LP

 

Gas

 

Natural

 

Gas

 

Test

 

Point

 

Pressure

 

2.75KPA

 

1.0KPA

 

Main

 

Burner

 

(injector

 

size)

 

0.98mm

 

1.50mm

 

Model

 

No

 

BBQ

AK600EB

 

Universal

 

LP

 

Gas

 

Natural

 

Gas

 

Total

 

Nominal

 

Gas

   

Consumption

 

(

 

MJ/h)

 

78

 

66

 

Main

 

Burner

 

Nominal

   

Gas

 

Consumption

 

(

 

MJ/h)

 

13x6

 

11x6

 

Содержание BBQ-AK600EB

Страница 1: ...D AND ASSEMBLED FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DAMAGE PLEASE RETAIN THE MANUAL FOR FUTURE REFERENCE CONVERSION TO NATURAL GAS SHOULD ONLY BE CARRIED OUT BY AUTHORIZED PERSONS PLEASE ENSURE THAT YOU REMOVE ALL PACKAGING AND TRANSIT PACKING PRIOR TO USE DO NOT SPRAY AERSOLS IN THE VICINITY OF THE APPLIANCE WHILE IT IS IN OPERATION ...

Страница 2: ...al wall area is completely open and At least 30 of the remaining wall area is open and unrestricted See Figure 4 5 l In the case of balconies at least 20 of the total of the side back and front wall areas shall be and remain open and unrestricted The following diagrams provide a diagrammatic representation of outdoor areas Rectangular areas have been used in these figures the same principles apply...

Страница 3: ...ve the gas cylinder from the enclosure before disconnecting the regulator from the appliance Tighten all connections before placing the gas cylinder back in its enclosure The gas leak testing procedure should be conducted every time the gas cylinder is refilled and reconnected to the appliance before using the appliance Regulator Connection 1 Check that all control knobs are in the Off position 2 ...

Страница 4: ...as work table do not put anything on the side burner lid while it is not working Lighting the Appliance 1 Open the lid and make sure all the knobs are in the OFF position 2 Push down the knob and turn the knob anticlockwise to HIGH position then keep pressing the igniter for 2 3 seconds a sound can be heard thus the burner will ignite If the burner does not light turn off the knob and wait for 5 m...

Страница 5: ...cleaners as it will damage parts of the product and may start a fire Stainless steel surfaces Stainless steel will corrode if not maintained To maintain your grill s high quality appearance wash with mild detergent and warm soapy water and wipe dry with a soft nonabrasive cloth after each use For further information please refer to our website Cooking grid Use a mild soapy water solution Non abras...

Страница 6: ...rs and other insects climb into the grill tubes attached to the burners The spiders spin webs build nests and lay eggs The webs or nests can be very small but they are very strong and can block the flow of gas Clean burners prior to use after storing at the beginning of grilling season or after a period of one month not being used Spider guards are on the air intakes in an effort to reduce this pr...

Страница 7: ... for use with this appliance is 9kgs The thread type of this appliance is G1 4B 19 Gas Type Universal LP Gas Natural Gas Universal LP Gas Natural Gas Test Point Pressure 2 75KPA 1 0KPA Main Burner injector size 0 98mm 1 50mm Model No BBQ AK600EB Universal LP Gas Natural Gas Total Nominal Gas Consumption MJ h 78 66 Main Burner Nominal Gas Consumption MJ h 13x6 11x6 ...

Страница 8: ...ASSEMBLY INSTRUCTIONS Tools required 1 Philips Screwdriver 2 Gloves if necessary ...

Страница 9: ...1 Foot Assembly 2 Flame tamer assembly ...

Страница 10: ...3 Cooking grid plate assembly 4 Warming rack assembly ...

Страница 11: ...5 For Battery Battery is not included ...

Страница 12: ...DO NOT block any ventilation slots of the BBQ 4 The enclosure material for the cutout should not be combustible 5 Do Not place gas cylinder underneath the barbecue keep required clearance 6 Ensure floor clearance and the cavity underneath the barbecue are kept PRODUCT DIMENSION WARNING Minimum clearance to combustible material under fat tray is 150mm ...

Страница 13: ...with AS5601 Gas installations pipe sizing tables and shall not exceed 3 meters in length The internal diameter of the hose must not be less than 10mm 3 All gas pipe connections must be sealed with a gas pipe compound resistant to natural gas NOTE TO INSTALLERS 1 The U LPG injector is 0 98mm 2 The NG injector for main burners is 1 50mm 3 The BBQ is set for NG by the manufacturer 4 Please read the f...

Страница 14: ...l and workmanship when subjected to normal domestic use and service for five years from the original purchaser This warranty is limited to the replacement of defective parts with the owner paying all other costs including labor Limited 2 Year Warranty The gas valves ignitions and burner covers are warranted to be free from defects in material and workmanship when subjected to normal domestic use a...

Отзывы: