Alfred DB1-B Series Скачать руководство пользователя страница 4

Factory Default Settings

Lock Operation

-Change Default Master PIN code

1. Touch the screen with your hand to activate.
2. Enter “*” twice and the 8-digit default Master PIN Code(12345678) followed by “#”. 
    Succeed: Beeper sounds “di-di”, green indicator flashes. 
    Failed: Beeper sounds “di-di-di”, red indicator flashes.
3. Enter “1+ new Master PIN code + #”, lock response: Refer to response upper.
4. Enter “new Master PIN code + #”, lock response: Refer to response upper.

-Add Up User PIN Codes

User PIN codes can be programmed through the Master PIN Code or APP.

1. Touch the screen with your hand to activate.
2. Enter “*” twice and the Master PIN Code followed by “#”.Lock Response: 
    Succeed: Beeper sounds “di-di”, green indicator flashes. 
    Failed: Beeper sounds “di-di-di”, red indicator flashes.
3. Enter “2 + User Number(00-19)” followed by “#”. Lock Response: Refer to response upper.
4. Enter User PIN Code(4-10 digits) followed by “#”. Lock Response: Refer to response upper.
5. Do step 4 again. 

When registering User PIN Codes, the code must be entered within 10 seconds or time expires. No matter setting succeed or failed, the process 
will complete and exit Master Mode.

-Delete User PIN Code

User PIN codes can be programmed through the Master PIN Code or APP.

1. Touch the screen with your hand to activate.
2. Enter “*” twice and the Master PIN Code followed by “#”. Lock Response:
    Succeed: Beeper sounds “di-di”, green indicator flashes. 
    Failed: Beeper sounds “di-di-di”, red indicator flashes. 
3. Enter “3+User Number(00-19)” and followed by “#”. Lock Response: Refer to lock response upper.
4. To continue deleting users, do previous steps from 1-3 again.

When deleting User PIN Codes, the User Number must be entered within 10 seconds or time expires. 
No matter setting succeed or failed, the process will complete and exit Master Mode.
Deleting all User PIN codes could be done only by resetting to factory default settings.

-Auto Re-lock enable/disable

Auto Re-lock feature can be programmed through the Master PIN Code or Alfred APP.

1. Touch the screen with your hand to activate.
2. Enter “*” twice and the Master PIN Code followed by “#”.  
3. Enter “41+ #” to enable Auto Re-lock.
    Enter “42+ #” to disable Auto Re-lock.(Default setting)

Wrong Code Entry Limit: 

After a specified number of unsuccessful attempts at entering a valid PIN code the lock will shut down and not allow operation. Wrong code entry limit is 
10 times.

Reboot button: 

When the system crash down, the lock could be restart by pressing Reboot button on outside escutcheon.

Reset button: 

After reset operation, the lock will be restored to factory default settings, all user credentials will be deleted. Refer to reset guide.

Definitions

Master PIN Code

Auto Re-lock

Beeper

Wrong Code Entry Limit

Shutdown Time

12345678

Disabled

Enabled

10 times

5 mins

Lock Operation

Before changing default Master PIN code, all other setting menu are disabled.
You have to change Master PIN code first, then do other lock settings.

Bluetooth

Disabled(Energy saving)

Settings

Factory Defaults

5/9

4/9

Содержание DB1-B Series

Страница 1: ...DB1 B Series Programming Instructions ...

Страница 2: ...om an interactive touch screen that makes day to day access effortless as well as offering voice guided programming for simple updates to user information in the event of staffing changes or security breaches Alfred DB2 is engineered for quick and easy installation and fits in place of a standard deadbolt lock door prep If this is an Wireless enabled lock it needs to located within 50 100 feet of ...

Страница 3: ...will extend the bolt during Auto Re Lock duration or when Manual Mode is enabled Shutdown Time The lock will shutdown for a default of 5 mins and not allow operation after the wrong code entry limit 10 times has been met When the unit is in Shutdown the screen will flash when you are trying to use keypad Away Mode This feature is enabled by the Master PIN Code in Master Mode or Alfred APP it restr...

Страница 4: ...Beeper sounds di di di red indicator flashes 3 Enter 3 User Number 00 19 and followed by Lock Response Refer to lock response upper 4 To continue deleting users do previous steps from 1 3 again When deleting User PIN Codes the User Number must be entered within 10 seconds or time expires No matter setting succeed or failed the process will complete and exit Master Mode Deleting all User PIN codes ...

Страница 5: ...in function extension can only be programmed through the Master PIN Code Refer to Network setting introduction If the lock is connected to a network controller it is recommended that it is programmed through the centralized user interface PC or hand held device to ensure communication between the lock and the controller Bluetooth feature can be programmed through the Master PIN Code or Alfred APP ...

Страница 6: ...e followed by 2 3 Enter 81 to pair Enter 82 to unpair Micro USB emergency power supply and Reboot button Micro USB power port Reboot button Door lock can be connected to micro USB power bank when battery wears out Door lock can be restarted by press Reboot button when crash down How to use Unlock the door 1 Unlock the door from outside Use PIN code key 2 Unlock the door from inside Manual thumb tu...

Страница 7: ...l interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver...

Отзывы: