Programming

Master and User PIN code have 4-10 digits, the default Master PIN code is  [12345678]. Please change it prior to programming of the lock.

Status Indicators
1#. Unlocked or setting succeed 
2#. Locked or setting failed
3#. Low battery Warning

Battery
cover

Thumb turn

Status indicator(Red) 2#

Status indicator(Green) 1#

Cylinder(optional)

Touch screen keypad

Status indicator(Battery) 3#

Reset button

Micro USB
power port

Reboot button

The default Master PIN Code must be changed after installing.  The Master PIN Code will also operate the lock in Away Mode.

Auto Re-lock: 

After successful PIN Code entry and the unit unlocks, it will automatically re-lock after 30 seconds. This feature is disabled in default
setting. Could be set up in Master Mode or through Alfred APP. 

Manual Mode:

 

Auto Re-lock function could be adjusted to Manual Mode. In Manual Mode the lock could be locked only by pressing any key for 2 seconds from outside 
or using thumb turn from inside.

One Touch Re-lock:

 

When the bolt is retracted, activating the keypad and press any key for 2 seconds will extend the bolt(during Auto Re-Lock duration or when Manual 
Mode is enabled)

Shutdown Time: 

The lock will shutdown for a default of 5 mins and not allow operation after the wrong code entry limit(10 times) has been met. When the unit is in 
Shutdown, the screen will flash when you are trying to use keypad.

Away Mode: 

This feature is enabled by the Master PIN Code in Master Mode or Alfred APP, it restricts all user PIN code access, except Master PIN code and APP
access. This feature will disabled automatically after entering Master PIN Code from outside or using APP. If someone unlock the unit by using thumb
turn or key override, the lock will alarm for 1 min and send a message to user’s hand-held device for warning(requires wireless module).

Silent Mode: 

Enabling Silent Mode shuts off the code confirmation tone playback for use in quiet areas. Silent mode is selected in the Voice setting of Master Mode or
Alfred APP.

Status LED: 

Located on outside escutcheon.

User PIN code: 

The User PIN code operates the lock. Maximum number of user PIN codes is 20.

Definitions

Master Mode: 

The Master Mode could be entered by entering “**+Master PIN Code+#” to programming the lock.

Master PIN code: 

The Master PIN Code is used for programming and for feature settings. 

3/9

2/9

Содержание DB1-B Series

Страница 1: ...DB1 B Series Programming Instructions ...

Страница 2: ...om an interactive touch screen that makes day to day access effortless as well as offering voice guided programming for simple updates to user information in the event of staffing changes or security breaches Alfred DB2 is engineered for quick and easy installation and fits in place of a standard deadbolt lock door prep If this is an Wireless enabled lock it needs to located within 50 100 feet of ...

Страница 3: ...will extend the bolt during Auto Re Lock duration or when Manual Mode is enabled Shutdown Time The lock will shutdown for a default of 5 mins and not allow operation after the wrong code entry limit 10 times has been met When the unit is in Shutdown the screen will flash when you are trying to use keypad Away Mode This feature is enabled by the Master PIN Code in Master Mode or Alfred APP it restr...

Страница 4: ...Beeper sounds di di di red indicator flashes 3 Enter 3 User Number 00 19 and followed by Lock Response Refer to lock response upper 4 To continue deleting users do previous steps from 1 3 again When deleting User PIN Codes the User Number must be entered within 10 seconds or time expires No matter setting succeed or failed the process will complete and exit Master Mode Deleting all User PIN codes ...

Страница 5: ...in function extension can only be programmed through the Master PIN Code Refer to Network setting introduction If the lock is connected to a network controller it is recommended that it is programmed through the centralized user interface PC or hand held device to ensure communication between the lock and the controller Bluetooth feature can be programmed through the Master PIN Code or Alfred APP ...

Страница 6: ...e followed by 2 3 Enter 81 to pair Enter 82 to unpair Micro USB emergency power supply and Reboot button Micro USB power port Reboot button Door lock can be connected to micro USB power bank when battery wears out Door lock can be restarted by press Reboot button when crash down How to use Unlock the door 1 Unlock the door from outside Use PIN code key 2 Unlock the door from inside Manual thumb tu...

Страница 7: ...l interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver...

Отзывы: