20
Detailed Performance Data for the TMC 600R on Round Pipes
Values shown for the performance of the TMC 600R are based on measurements made on round pipes with
material S235 JR, comparable to AISI 1020 Cold Rolled Steel, for the maximum, vertical breakaway force at
0° deviation from the load axis and a correct position in the groove of the magnetic contact area. These values do
not include any safety factor. The magnetic clamp will detach itself abruptly when the load exceeds values given in
table 3.
Table 3 Round pipes
mm
Breakaway force in kg
50
75
100
200
300
3
140
175
160
175
-
4
175
220
200
220
-
5
210
265
245
265
-
8
230
290
260
290
-
>10
240
300
275
300
Inches
Breakaway force in lbs
2“
3“
4“
8“
12
“
1/8
308
385
352
385
-
0.16
385
484
440
484
-
0.2
462
583
539
583
-
5/16
506
638
572
638
-
>3/8
528
660
605
660
Table 4: Air gap with round pipes
Avoid quick and abrupt rotations of the magnetic clamp especially when used on round objects
since the workpiece could disengage from the groove of the magnet causing a sudden reduction
of the load-bearing capacity.
Air gap in mm
0
0,2
0,4
0,6
1,0
1,5
Air gap in inches
0
0,0078 0,0157 0,0236 0,0393 0,0590
Residual breakaway
force
100%
85%
70%
55%
35%
22%