Detailed performance data for the switchable magnetic clamp TMC 300
Values shown for the performance of the TMC 300 are based on measurements made on material S235 JR,
comparable to AISI 1020 Cold Rolled Steel, for the maximum, vertical breakaway force at 0° deviation from the
load axis and additionally under a 90° inclined load. These values do not include any safety factor. The magnetic
clamp will detach itself abruptly when the load exceeds values given in table 2.
Table 2
Breakaway force in kg
Thickness of
material
Clean, flat, ground
surface
Rusty, slightly
scratched surface
Irregular, rusty or
rough surface
Air gap <0.1 mm
Air gap = 0.25 mm
Air gap = 0.5 mm
mm
0°
90°
0°
90°
0°
90°
2
90
30
75
25
66
22
3
150
50
120
40
105
35
4
240
80
180
60
135
45
5
285
95
210
70
150
50
>6
300
100
210
70
150
50
Breakaway force in lbs
Thickness of
material
Clean, flat, ground
surface
Rusty, slightly
scratched surface
Irregular, rusty or
rough surface
Air gap <0.004 inches
Air gap = 0.01 inches
Air gap = 0.02 inches
Inches
0°
90°
0°
90°
0°
90°
0.08
198
66
165
55
150
50
0.12
330
110
270
90
225
75
0.16
540
180
390
130
300
100
0.20
630
210
465
155
330
110
>0.25
660
220
465
155
330
110
During each application, watch for any deformation of the work piece that might occur. If an air gap forms between
the magnetic surface and the work piece, the magnetic clamp will not reach the stated holding force and could
detach itself. Please check for any air gap developing at the edges of the TiN-coated magnetic surface if necessary
(e.g. with a sheet of paper; 80g/m
2
).
Immediately stop the operation if there is any excessive deformation of the work piece or if an
air gap occurs.
Never exceed the dimensions and/or the load-bearing capacity of the material thickness given
In table 2.