alfen Eve Single Pro Series Скачать руководство пользователя страница 1

Eve Single

 –

Manual / Handleiding / Handbuch / Manuel / Käyttöopas

S-line
Pro-line

Содержание Eve Single Pro Series

Страница 1: ...Eve Single Manual Handleiding Handbuch Manuel K ytt opas S line Pro line...

Страница 2: ......

Страница 3: ...socket model met stopcontact Modell mit Steckdose mod le avec prise pistorasialla varustettu malli INSIDE BINNENZIJDE INNENSEITE INT RIEUR SIS PUOLI OUTSIDE BUITENZIJDE AUSSEN EXT RIEUR ULKOPUOLELLA...

Страница 4: ...t model met stopcontact Modell mit Steckdose mod le avec prise pistorasialla varustettu malli Exterior view Buitenzijde Aussenansicht Ext rieur Ulkopuolella 1 1 3a 3b 2 2 11 10a 8 9 10b 11 11 10a 11 7...

Страница 5: ...ilisation of all advanced features of your charging station we recommend that you read this manual carefully and save it for future reference While we have done our utmost to provide you with a comple...

Страница 6: ...s 14 2 6 Accessories 15 2 7 Technical specifications for installation 16 2 7 1 External protection according to EV ZE Ready standard 16 3 Assembly and connecting 16 3 1 Safety Instructions 17 3 2 Asse...

Страница 7: ...individual components are damaged Usage by children or individuals not able to properly assess the risks associated with using this product Alfen ICU B V shall not be liable in any way for any kind o...

Страница 8: ...or plug holder 4 RGB Status LED Interior view Interior view 5 UTP Ethernet connector 5 UTP Ethernet connector 6 RJ11 connector 6 RJ11 connector 7 7 SIM cardholder 8 Terminal block for the power supply...

Страница 9: ...Charge card accepted cable connected Communicating with vehicle or charging complete Charging transaction active Status indicators during smart EV charging load balancing The Eve Single S line will i...

Страница 10: ...3 2 3 Operation Specific user actions are presented in a sequence that cearly shows the progress and corresponding status indications The first steps can be conducted in any sequence Upon detecting a...

Страница 11: ...h h kW kW kWh h Models with fixed charging cable Models with socket Models with socket Models with fixed charging cable Pro line Pro line Pro line Pro line 2 4 1 3 2 4 1 3 2 4 1 3 2 4 1 3 RFID Chargin...

Страница 12: ...to undo the action To close the database hold the Master Key in front of the card reader once more Hold the Master Key in front of the card reader Hold the charge pass that you want to add in front o...

Страница 13: ...C detector that protects the earth leakage circuit breaker against DC leak age currents The DC detector prevents type A earth leakage circuit breakers from becoming blind to dangerous leakage currents...

Страница 14: ...ts default casing colour RAL9016 Other darker colours may have an adverse effect on the product If the product is exposed to lower or higher temperatures continuous operation cannot be guaranteed If t...

Страница 15: ...x Quick Installation Guide 1 x M8 nut 4 x M25 x 1 5 For model with fixed charging cable 2 x 2 PRODUCT 2 6 Accessories Item Details Article no Mounting post 803873036 ICU Pole dimensions H x W x D Bas...

Страница 16: ...ase 16A 11kW 3 x 20A gG 1 phase 32A 7 4kW 1 x 35A gG 3 phase 32A 22kW 3 x 35A gG Residual current protection possibly i c w circuit breakers Earth leakage circuit breakers 30mA type A or B 4P 3 7kW 11...

Страница 17: ...short circuiting and overcurrent with a B or C type circuit breaker or other in accordance with local standards and regulations or gG type fuses or other in accordance with local standards and regula...

Страница 18: ...ring and the construction Spirit level Drill machine Torque driver for terminal block connections 3 5 Installation procedure prerequisites The installation location is a solid wall In the surroundings...

Страница 19: ...ount the charging station on the wall mount frame Connect the earth wire on the bottom right threaded end of the wall mount frame Use the M8 washer and nut for installation 3 7 Electrical installation...

Страница 20: ...tion Screw the front cover back onto the charging station with the Torx T20 wrench Use all six screws for this Models with display Connect the display connector 3 10 Data cable options 3 10 1 Connecti...

Страница 21: ...ionality If so check the settings with the Service Installer application to optimally configure the charging station for the local situation More information is available in Appendix B 4 3 Commissioni...

Страница 22: ...the smart charge options see Appendix B check the settings and adjust them where necessary to optimally configure the charging station for its location The Service Installer application is divided in...

Страница 23: ...isconnect the transpa rent subframe 3 x Torx T20 screw To install a card access the SIM cardholder from the left side This will provide you with more space Be careful not to crush any cables while rep...

Страница 24: ...4460127 Eve Single Pro line DE 3PH Cable NG910 60127 904460503 Eve Single S line 1PH T2 NG910 60503 904460505 Eve Single S line 1PH T2S NG910 60505 904460507 Eve Single S line 1PH Cable NG910 60507 90...

Страница 25: ...charge point supplier Check powerboard 105 Not able to charge Please call for support Internal error No communication with internal power meter Contact the service department of your charge point supp...

Страница 26: ...Cable connected for more than 2 minutes without starting a charging session Reconnect cable and start charging session within 2 minutes Otherwise contact the service depart ment of your charge point...

Страница 27: ...ging cable is out of range according to the IEC 61851 norm One specific cable Issues with other charge points Cable broken All cables No issue with oth er charge point Contact the service department o...

Страница 28: ...20 metres combined with the P1 port Always check if the communi cation with the smart meter is working properly The quality of the signals depend on several factors Therefore always limit the cable le...

Страница 29: ...e network operator Subnet mask of the local network Modbus address of the energy meter Default gateway of the local network Factory settings Options Values SCN NetworkName Name of the SCN Maximum of 8...

Страница 30: ...0 1 W SIGNED32 Reactive Power L1 VAr 0 1 VAr SIGNED32 Reactive Power L2 VAr 0 1 VAr SIGNED32 Reactive Power L3 VAr 0 1 VAr SIGNED32 Apparent Power L1 VA 0 1 VA UNSIGNED32 Apparent Power L2 VA 0 1 VA...

Страница 31: ...0Mbps network UDP port 36549 inbound outbound Use the DHCP server if possible Without a DHCP server the charging stations obtain an IP address via Auto IP All charging stations are fed from the same p...

Страница 32: ...e SCN if you have not purchased this functionality After you receive confirmation for your purchase of this functionality by Alfen the new functionality can be downloaded using the Service Installer a...

Страница 33: ...ely For this purpose all local authorities have established collection schemes under which residents can dispose waste electrical and electronic equipment at a recycling centre or other collection poi...

Страница 34: ......

Страница 35: ...1 0 36 54 93 401 Website www alfen com nl oplaadpunten ev www alfen com en ev charge points Contact Contact Kontakt Contact Yhteystiedot Alfen ICU B V Hefbrugweg 28 1332 AP Almere The Netherlands P O...

Отзывы: