3. INSTALLING AND CONNECTING

Image 2: Fixing the cable cover

Preparing the charging station

Do not remove the transparent foil from the casing during 
installation. This helps to prevent damage such as scratches 
on the display. Before installation, the white cover must be 
removed from the charging station. This is done as follows:

The front cover is firmly attached to the charging station 
and is secured with two screws at the top and bottom.

1.

  lace the device on its back, preferably on a soft under 

 

ground such as the packaging of the Eve.

2.

  Loosen the screws on the bottom with an Allen key.

3.

  Use a Torx m5 (T25) screwdriver to loosen the two  

 

screws on the side of the backside of the casing (ref.  

 

image 3).

4.

  Save these screws somewhere safe, they are required  

 later.

5.

  Carefully lift the white cover, starting at the bottom in  

 

an upwards direction.

6.

 Take the entire white part of the unit and put it at a  

 

safe location where it cannot be scratched or dama 

 

ged otherwise; for instance in the packaging of the  

 

Eve. Be particularly careful with the display screen.

Image 3: Location of Torx T25 bolts to release, adjust and fasten 
the enclosure

Installing the charging station

1.

  Place the casing onto the already installed mounting  

 

block, in a vertical downward movement.

2.

  Attach the casing on the top side with two screws  

 

(max. diameter 8mm) at the right position (ref. image  

 4).

Image 4: Wall mounting

3.4 Electrical installation

 

WARNING

Carefully read and follow all safety instructions in this 
manual!

 

DANGER!

The electric system must be completely disconnected from 
every power supply prior to carrying out installation and 
maintenance work!

1.

  Pull the power cable through the cable inlet,

 (

5

 on page 2).

2.

  Pull the power cable at least 15 cm into the housing  

 

from the ground or wall.

3.

  Secure the power cable in the cable inlet by 

 

tightening it so that the power cable cannot be 

 

removed. The cable gland also functions as a strain  

 relief. 

4.

  The subframe with the type 2 charging sockets must  

 

be detached, refer to images 5 and 6. The subframe is  

 

equipped with a clicking mechanism on all four  

 

connection points. Detaching the subframe is best  

 

done by first detaching one side (left or right) 

 

followed by the other side.

Содержание 904461001

Страница 1: ...Eve TM Model 2017 2 0 Manual Handboek Handbuch Manuel...

Страница 2: ...2 OUTSIDE BUITENZIJDE AUSSENSEITE EXT RIEUR 1 3 5 6 7 5 2 4 6 5 8...

Страница 3: ...3 INSIDE BINNENZIJDE INNENSEITE INT RIEUR 9 13 10 9 11 12 14...

Страница 4: ...4...

Страница 5: ...lly utilise all advanced features of your new system we advise you to read this manual carefully Properly store this manual for future usage We have invested a great amount of care to provide you with...

Страница 6: ...rging station 18 4 1 Safety instructions prior to usage 18 4 2 Commissioning 18 5 Connectivity 19 5 1 Administration systems 19 5 2 Establishing a connection 19 5 2 1 Wireless connection 19 5 2 2 UTP...

Страница 7: ...eral safety DANGER The safety instructions are intended to ensure proper practical usage If you do not comply with these safety regulations and instructions you may expose yourself to the risk of elec...

Страница 8: ...lour display to visualise the status of the charging station and inform the user about the charging progress 23 10 2017 12 30 Please hold card over reader below To stop charging please hold card over...

Страница 9: ...1 0 July 2017 ENGLISH 2 PRODUCT 2 3 Operating the charging station Plug Charge No charge card authorisation required RFID Charging station with user authorisation Start Stop Start 1 1 1 1 2 2 2 2 3 3...

Страница 10: ...site short circuit protection For 2x3 7kW 11kW 40A B residual current fuse or 35A gG fuses Load balancing optional For 2x7 4kW 22kW 40A B residual current fuse or 35A gG fuses Load balancing required...

Страница 11: ...7 4kW charging 32A selected per phase 904461011 3 x 6mm2 904461012 3 x 6 mm2 per cable 3 phase 22kW charging 32A selected per phase 904461001 5 x 6 mm2 904461002 5 x 6 mm2 per cable Nominal current 23...

Страница 12: ...ay have an adverse effect on the temperature range The temperatures mentioned above apply for the ambient temperature of the product assuming the standard colour of the casing RAL9016 Other darker col...

Страница 13: ...e RFID Maximum available charging current per socket 16A 32A Smart charging options Off Standard load balancing Active load balancing P1 Own logo shown on colour display Off Alfen logo On Your own log...

Страница 14: ...omponents that may still contain electrical charge after being disconnec ted Wait at least 10 seconds after disconnection before commencing work DANGER The electric system must be entirely disconnecte...

Страница 15: ...side of the charging station is covered to prevent it from being unintentionally disconnected or used by unauthorised individuals 3 3 Mechanical installation Use the following tools and equipment to i...

Страница 16: ...instance in the packaging of the Eve Be particularly careful with the display screen Image 3 Location of Torx T25 bolts to release adjust and fasten the enclosure Installing the charging station 1 Pl...

Страница 17: ...ide the charging station are enabled 9 Put the isolating switch on the I ON position If useful use a special wrench to simplify switching 10 Press the white part of the casing in the orifices on the t...

Страница 18: ...llowing actions are performed 1 The display briefly illuminates and then switches off 2 The sockets are tested individually testing locking testing internal relays switching is audible 3 The display b...

Страница 19: ...allation is complete always verify the signal strength using the Service Installer REMARK A connection with an administration system can only be established if you made arrangements with the supplier...

Страница 20: ...he Alfen website 2 Please fill in the numbers on the back of the charge cards delivered to you in the Remarks field 3 Click on Send 4 Alfen will process your application and activate your account You...

Страница 21: ...ug You can now start a new session 007 Charging error vehicle will not shut down Contact the service department the vehicle might not be responding correctly 101 Residual current device deactivated Co...

Страница 22: ...ommunicate with each other over the P1 port using the DSMR protocol version 4 0 or higher Data about the actual consumption and charging needs is regularly exchanged Whenever smart meter capacity is l...

Страница 23: ......

Страница 24: ...kt Contact Alfen ICU B V Hefbrugweg 28 1332 AP Almere The Netherlands P O box 1042 1300 BA Almere The Netherlands Tel Sales Support 31 0 36 54 93 402 Tel Service 31 0 36 54 93 401 Website ww alfen com...