ALF-IP6
16
4.4.5 Compare Setting
This item is used for comparing the feedback of the RS232 commands. When the
ALF-IP6 sends an RS232 command to the controlled device, the device will send
feedback. If the correct feedback is added in the data, the ALF-IP6 will compare it with
the feedback received from controlled device, to verify whether the command is working
or not. The “Compare” setting is as below:
Operation procedure:
1)
Select the button action in the action list.
2)
Select the RS232 port. The port must be same as the model setting, or the event
cannot be added.
3)
Set the command format ASCII or Hex, if selecting ASCII then the end character
must be set.
4)
Enter the RS232 command which needs to be compared in data box, then press
“add” to save the setting.
5)
Add an event that the LED lights up to indicate the comparative result.
6)
For events in one event list, a priority is followed, from top to bottom, so that the
compare function can be used in action which has three or more events.
Enter the compare commands,
DO NOT miss any characters.