background image

ALF-IP6 

 

Buttons 1 through 6, correspond to the physical buttons on ALF-IP6. Click on button 1, 

the following dialog window will pop up: 

 

 

 

4.3 Action List 

All Panel Set actions will be shown on the action list and available actions must be 

added to the list. The action list is as the picture below: 

 

Key Type: 

1. Press: Execute events when 

button is pressed. 

2. Release: Execute events when 

button is released. 

3. Toggle: The button can be 

regarded as composite key, 

press the button twice to 

execute different events. 

Built key group for LED setting. 

Delete the selected action. 

Delete all invalid actions. 

Empty all actions. 

Содержание ALF-IP6

Страница 1: ...www alfatronelectronics com ALFATRON ELECTRONICS GmbH GERMANY ALF IP6 Wallplate Control Panel 6 buttons All Rights Reserved Version ALF IP6_2021V1 1...

Страница 2: ...his equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications It has been...

Страница 3: ...l this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose you to dangerous volt...

Страница 4: ...tware 4 4 1 Basic Setting 4 4 2 Panel Set 7 4 3 Action List 8 4 4 Event setting 9 4 4 1 RS232 Setting 9 4 4 2 IR Setting 11 4 4 3 TCP IP Setting 14 4 4 4 Delay setting 15 4 4 5 Compare Setting 16 4 4...

Страница 5: ...third party devices Each button can be programmed to send the IR codes simultaneously to control the third party devices and support IR code learning function The unit may be programmed through the E...

Страница 6: ...Illuminates red when powered on 2 Button Six crystal and luminescent programmable buttons Each button can be programed with the Control Panel Software Each label within a button can be easily changed...

Страница 7: ...RS232 1 RS232 3 Total of three RS232 ports Connect to third party devices which need to be controlled via the Control Panel Software 6 PWR 12V Connects with 12V DC power adaptor 7 IR 1 IR 2 Two IR ou...

Страница 8: ...IR 2 TX RX 12V PWR TX RX ETHERNET IR IR IR IR Remote IR Emitter IR Emitter IR TCP IP RS232 1 Wireless Route System Diagram 1 Connect the ALF IP6 to the LAN port of a Wireless Router or control device...

Страница 9: ...default IP of the ALF IP6 wallplate is 192 168 0 178 modifiable the control PC should have its network segment the same as the ALF IP6 s Modify the IP of the PC 3 Install uninstall Control Panel Soft...

Страница 10: ...s Panel Set TCP IP Action List Event Set and Event List The main window of the Control Panel Software is shown as below Panel Set Click 1 6 to set key action Show IP addresses of all connected devices...

Страница 11: ...and MAC address Click File Software Update Hold down the 3 button and power on the system until the button lights up to enable update mode Open upgrade Web page http 192 168 0 178 4001 on IE Type Use...

Страница 12: ...et Total of six customizable buttons on the front panel can be set via this software Add a button action to show the action list then add events to ensure this action will execute the events How to se...

Страница 13: ...st and available actions must be added to the list The action list is as the picture below Key Type 1 Press Execute events when button is pressed 2 Release Execute events when button is released 3 Tog...

Страница 14: ...is used for setting the events for RS232 1 RS232 3 ports Click RS232 it will show as below Operation procedure 1 Select the button action in action list 2 Set the Lib name and Lib Function This is an...

Страница 15: ...ile as below Note Once set up please press Save to save the edit or Save as to save as a file and then press OK 7 There are two Delay Send Set and None When selecting Set the number of sending strings...

Страница 16: ...ALF IP6 11 4 4 2 IR Setting This item is used for setting the events for IR 1 IR 2 ports Click IR it will display as follows...

Страница 17: ...ry file as below Note Once set up please press Save Edit to save the edit or Save as to save as a file and then press OK IR Learning Procedure 1 Click learn to enter IR learning mode 2 Put the IR Remo...

Страница 18: ...ALF IP6 13 6 There are two Delay Send Set and None When selecting Set the number of sending strings and the delay time between strings can be set...

Страница 19: ...4 4 3 TCP IP Setting The TCP IP port supports pass through function You can set the events for different IP port via commands Type the IP address of the device that needs to be set Type in the contro...

Страница 20: ...Delay setting This item is to add a delay between two events when one event is completed it will delay a certain time then start the next event The delay setting is as picture below Hour 0 24 Minute...

Страница 21: ...1 Select the button action in the action list 2 Select the RS232 port The port must be same as the model setting or the event cannot be added 3 Set the command format ASCII or Hex if selecting ASCII...

Страница 22: ...s in ALF IP6 to turn on or off The setting is as follows 1 On Turn on the LED of button 1 2 Off Turn off the LED of button 1 3 On Other Off Turn on the LED of button 1 and turn off the others 4 On Gro...

Страница 23: ...button type can be set as Toggle in this type the button can be regarded as a composite key Below is an example to show you the use of this function Operation procedure 1 Take Key 1 for example click...

Страница 24: ...ALF IP6 19 2 Add toggle RS232 events for the Button 1...

Страница 25: ...cuted 4 5 Event List The event list shows all events of the selected action The executing priority abides by the Num order as displayed below If there is an event executed incorrectly all the events t...

Страница 26: ...x 2 Pin Pluggable terminal blocks Baud Rate and Protocol 9600 baud 8 data bits 1 stop bit no parity Software ALF IP6 Power Consumption 1W Max Operation Temperature 0 40 Storage Temperature 10 55 Relat...

Страница 27: ...ALF IP6 22 6 Panel Drawing...

Страница 28: ...e the network segment of the control PC and the ALF IP6 is the same 3 When the LED of a button does not light up please check if there is a compare event in this button If yes delete the compare and t...

Страница 29: ...od must be presented to obtain warranty service What the warranty does not cover servicing is available at a fee Warranty expiration Factory applied serial number has been altered or removed from the...

Страница 30: ...l maintenance Failure of the product due to insufficient or improper maintenance is not covered 1 4 The Company does not warrant that the product covered hereby including without limitation the techno...

Страница 31: ...roduct from or into any installation The Company will not be responsible for any costs related to any setting up this product any adjustment of user controls or any programming required for a specific...

Страница 32: ...ALF IP6 27 WARRANTY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT...

Отзывы: