5. Button Control
5.1 Manual Switching
When the switcher is in the manual switching mode, press the
SELECT AUTO/3s
button repeatedly to cycle through the two video inputs, and the corresponding source
LED illuminates orange immediately.
5.2 Automatic Switching
Press and hold the
SELECT AUTO/3s
button at least three seconds to enable
automatic switching. The current input source will not be changed, and its source LED
will turn green.
When in the AUTO mode, the switcher will switch according to the following rules:
Press and hold the
SELECT AUTO/3s
button at least three seconds again to exit
AUTO mode, but the input source will not be changed, and the corresponding
source LED will turns orange.
New input: Upon detecting a new input, the switcher will automatically select the
new input.
Press the
SELECT AUTO/3s
button can also forcibly change the input source.
Reboot: Once power is restored to the switcher, it will automatically reconnect the
input before powered off.
Source removed: When an active source is removed, the switcher will switch to the
other active input.
5.3 Display Control
Manual Control:
Press the below
DISPLAY
buttons on the front panel to
simultaneously send RS232 and CEC commands to control the display device.
ON: Display On.
OFF:
Display Off.
:
Mute/unmute display audio.
:
Volume down display audio.
:
Volume up display audio.