6.2 THERMO VALVE (Fig. 7, Item 13) 

Installation  of  a  thermo  valve  is  MANDATORY  in  a  closed  circuit.  This  specially  refers  to  a  closed  circuit, 
when the radiators are submerged and where, in the event that pump operation is stopped for any reason, water 
temperature in the boiler rapidly increases and overheating occurs very quickly. 
In central heating open circuits, installation of thermo valves is not mandatory. 
You can connect the thermo valve to the upper or lower R1/2" connection, depending on the available space, 
only you must observe the direction of water inlet and outlet, which is clearly marked on the valve body. 
Place the thermo valves safety pipe in the opening of the thermo valve connection (Fig. 4, Item 5 and Fig. 7, 
Item 18). Seal it with hemp or other sealing material by tightening. 
Fig. 7 shows the thermo valve installation diagram. 
 
 

6.3 SAFETY VALVE (Fig. 7 and 8, Item 5 and Fig. 4, Item 6) 

An R1/2" connection (Fig. 4, Item 6) is welded at the back of the boiler, under the cooktop frame, on which a 
safety valve MUST be fitted. The safety valve should be 2.5 to 3 bars. You can fit it directly on the connection 
or at a distance from the connection of at least 1 m, provided that there is no block valve between the boiler and 
the safety valve. 
In general, safety valve is not fitted in open circuits, but we advise you to fit it nonetheless, as another safety 
precaution for the boiler and the system (in case of emergency). 

NOTE: 
If the safety valve is not fitted as described above, the warranty will not be valid. 

 
 

6.4 THERMOMETER AND PRESSURE GAUGE (Fig. 1, Items 16 and 17 and Fig. 5) 

Thermometer and pressure gauge are installed on the stove, on the additional lid (Fig. 1, Item 24) between the 
firebox door and the ash pan door (Fig. 1, Items 16 and 17, and Fig. 5) and therefore it is not necessary to install 
them. 
Thermometer, Item 17, shows the temperature of water in the boiler (operating temperature) in ºC. 
Pressure gauge, Item 16, shows the pressure of water in the boiler or the system in bars. 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

 

Figure

 

5       

 

 

 

 

        Figure 6 

 

Содержание ALFA TERM-27

Страница 1: ...STOVE USED FOR LOCAL HEATING ALFA TERM 27 INSTALLATION SETUP AND OPERATION INSTRUCTIONS...

Страница 2: ...IONS Width 315 mm Height min max 264 460 mm Depth 414 mm FIREBOX DOOR OPENING width height 175 200 mm FLOW AND RETURN PIPE CONNECTIONS R1 RS THERMO VALVE AND SAFETY VALVE CONNECTIONS R1 2 RU COOLING P...

Страница 3: ...pipe connection 21 Cleaning access plate 22 Handle 23 Grate support 24 Additional lid 25 Lever support 26 Tertiary air regulator knob 27 Tertiary air regulator cover 28 Cleaning access plate smaller...

Страница 4: ...4 Figure 1...

Страница 5: ...t and not on the side outlet The stove will reach its nominal heating capacity if the draft in the chimney is 20 Pa A chimney ensuring good draft is the basis of proper functioning of the stove The ch...

Страница 6: ...walls it must be well insulated If the chimney connection is tightly connected to the chimney if the connection is extended If it is properly cleaned and free of birds nests dirt and soot If the flue...

Страница 7: ...ation of the thermo valve safety pipe Item 6 is an R1 2 connection with an inner thread for safety valve installation 6 1 FLOW PIPE AND RETURN PIPE Fig 4 Items 1 and 2 and Fig 7 and 8 Items 3 and 10 T...

Страница 8: ...R1 2 connection Fig 4 Item 6 is welded at the back of the boiler under the cooktop frame on which a safety valve MUST be fitted The safety valve should be 2 5 to 3 bars You can fit it directly on the...

Страница 9: ...expansion vessel of 25 l and not more than 18 l which should be fitted on the return pipe as close to the boiler as possible and no block valves can be fitted between the boiler and expansion vessel...

Страница 10: ...pe connection 3 Distribution pipe 4 Open expansion vessel 5 Safety valve 6 Radiator valve 7 Radiator 8 Air release valve 09 Circulation pump 10 Return pipe 11 Spigot for filling and discharge 12 Safet...

Страница 11: ...em should be filled with water and well bled and the stove should be properly connected to the chimney as described in the foregoing items NOTE The stove may not be used without water It must be conne...

Страница 12: ...of the grate and pull it out of its holder Place the grate on the supports 4 pcs welded inside the boiler firebox at the front and in the back 2 2 pcs Fig 1 Item 23 Place the grate at an angle slante...

Страница 13: ...e damper used for starting the fire must be closed and power regulator must be open After you finish baking cooking or frying place the power regulator in desired position While baking increase the te...

Страница 14: ...cloth cleaning agents and mild detergent instead Clean the oven after each use while still hot After cleaning leave the oven door open for a few minutes to prevent bad odors the next time you heat the...

Страница 15: ...n all valves in the heating system and enable normal water circulation in the system Circulation pump failure Repair or replace the circulation pump to enable heating system operation Power outage Ope...

Страница 16: ...mp speed Replace pump nuts or the entire pump 10 Noise murmur coming from the heating system Pump speed is too high Lower the speed Air in the system Bleed the air from the heating system Loose knobs...

Страница 17: ...oor 17 Excessive heat for baking or cooking Thermostat set to a high temperature Reduce water temperature using the thermostat or burn a smaller fire 18 Boiler stove is smoking when used for the first...