5 Maintenance
Read the instructions carefully. The items refer to the parts list and service kits section.
Lubricate the rubber seals before fitting them.
: Relates to the shaft seal.
Step 10
Fit safety guard (22) and screw (23) and tighten.
If the pump is not supplied with flush connections, the holes in the
adaptor must be covered by the guard.
3001-0037
Step 11
1. Fit pump casing (29), washers (24a) and cap nuts (24).
2. Tighten nuts (20) for back plate (25).
3. Tighten nuts (20) for back plate (25) and tighten cap nuts (24).
Torque values:
LKHex UP 10-20 = 20 Nm/14.8 lbf-ft
LKHex UP 25-70 = 40 Nm/29.5 lbf-ft
3001-0012