2.

 

PURPOSE 

 

Aesthetically very nicely shaped, continuously burning fireplace  – solid fuel stove for floor 

heating, fits in the interior of living rooms and remaining free space of the apartment. It is used 
for heating rooms, cottages, individual houses, different premises etc. The stove provides direct 
heating in the room where it is located, so no heating bodies are required in that room since the 
large glass screen (fig. 1 pos. 15) on the front door, as well as the stove casing and the cast cover 
provide equal heating of rooms by emission and convection. 

Special  characteristic  of  these  stoves  –  furnaces  is  that  they  have  built-in  snake  hose 

(copper pipe) which when connected to the thermal valve (fig. 7 and fig. 7a pos. 13) is used 
as a thermal fuse for eventual overheating of the stove – furnace.  

Installation of thermal valve in closed central heating system is COMPULSORY. 
In an open central heating system, installation of thermal valve is not compulsory. 
It is mainly installed as floor heating stove, but it can be installed for central heating as well. 
In  order  that  the  stove  operates  to  everyone’s  satisfaction,  the  user  must  adhere  to  all 

requirements of these instructions.       
 
 
 

 

3. STOVE COMPLETION 

 

Check  the  unpacked  stove  and  become  familiar  with  the  parts  and  accessories,  and 

especially pay attention to the following: 

-

 

the front  door (fig. 1 pos.  14) and the stoking door (fig. pos.33) should  be provided 
with  asbestos  tape  according  to  their  size  on  the  lying  part  of  the  surface  during 
sealing; 

-

 

the air regulator (fig. 4 pos. 1) through the command knob must easily open and close 
the butterfly of the opening for supply of air for combustion; 

-

 

well  installed  air  regulator  enables  selection  and  automatic  maintenance  of  water 
temperature in the stove; 

-

 

the remote thermometer for measuring the temperature in the boiler (fig. 1 pos. 16) is 
properly installed if its thermal probe is positioned in the special opening on the back 
side together with a thermal probe of the air regulator; 

-

 

the grate – grill (fig. 1 pos. 45) must be positioned in its bearing and connected to the 
grate shaker (fig.1 pos.45); 

-

 

the stove cap (fig. 1 pos. 1) can  be kept  in  lifted position  –  by  leaning on the brace 
(fig.1 pos. 28) on the cover of the combustion chamber (fig. 1 pos. 11). 

 
 
 
 
 
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     

 

Содержание RUSTIKAL ETAZ

Страница 1: ...Ul Radnicka 1 17500 Vranje Serbia Tel 017 421 121 INSTRUCTIONS FOR USE CONTINUOUSLY BURNING SOLID FUEL FIREPLACE FOR FLOOR HEATING WITH HOT WATER RUSTIKAL ETAZ...

Страница 2: ...re of distributing water 90 C 6 Required flue draft 15 Pa 7 Content of water in the fireplace boiler 11 l 8 Fireplace mass 133 kg 9 Volume of ash box 9 dm3 10 Space heating capacity 150 170 m3 11 Fire...

Страница 3: ...talled for central heating as well In order that the stove operates to everyone s satisfaction the user must adhere to all requirements of these instructions 3 STOVE COMPLETION Check the unpacked stov...

Страница 4: ...Fig 2 Opening the door for stoking Fig 3 Pulling out the ashtray Fig 4 Position 1 Air regulator Position 2 Butterfly opening...

Страница 5: ...LIGHT SURFACES mm coal 12 5 wood 14 145x145 125 145x145 125 Special note install a reducer on the flue connection fig 1 pos 7 which is delivered separately packed together with the stove thus reducing...

Страница 6: ...he axis of flue connection from the table with technical data This stove may be installed in the living room or some other free space in the apartment You must make sure that there is inflammable pad...

Страница 7: ...ns contain connective measures and contextual schemes for installing the stove in the floor heating system SCHEME OF CLOSED SYSTEM INSTALLATION Fig 7 1 Hot water boiler 2 Flue connection 3 Distributin...

Страница 8: ...ll and drain tap 12 Regulating valve 13 Thermal valve 14 Connecting line for water supply network 15 Hot water drain 16 Manometer 17 Safety valve connection 18 Thermal valve connection 19 Air vent IMP...

Страница 9: ...until the upper layer of coal or wood becomes ember Set the thermostat on the desired temperature in order to use to stove economically it should be filled with coal or wood up to the height of the fr...

Страница 10: ...es the intake of combustion air if the remaining openings are closed The functioning of the air cover flap is automatic and depends on the selected temperature on the knob as well as the water tempera...

Страница 11: ...re in contact with flue gases should be regularly maintained and cleaned by using a spade for cleaning The clean heating surfaces ensure economical operation of the stove Cleaning of the stove at leas...