DEAR CUSTOMERS! 

 
Thank you for purchasing the Grande 37 Lux boiler. Please read the entire instruction carefully before installing and 

commissioning your Grande 37 pellet boiler. Alfa Plam A.D. heating appliances (hereinafter referred to as "pellet boilers" or 
"boilers") have been designed, manufactured and tested in accordance with the requirements of the applicable European 
Directives on safety standards. 

These instructions are intended for end users, installers and technicians authorized for operations on Grande 37 pellet 

boilers. If you have any questions regarding the instructions or need any explanation, please directly contact the 
manufacturer or an Alfa Plam authorized vendor. 

Printing, translation or reproduction, as well as partial, of these instructions is only possible with the written permission 

of Alfa Plam. The boiler uses pellets as fuel. It operates automatically by dosing the pellet with a helical worm conveyor from 
the pellet tank, which is part of the device placed above the boiler part of the appliance. The pellet tank is filled from above 
through the designated lid. Make sure that the boiler is properly dimensioned with respect to the heating system and energy 
requirements of the facility. The appliance should be connected and commissioned by a person authorized by Alfa Plam. 

The flame that develops in the boiler during normal combustion of wood biomass releases just the amount of carbon 

dioxide (CO

2

) that would be released by natural wood decomposition. The amount of CO

2

 formed during combustion or 

decomposition of the wood corresponds to the amount absorbed by the tree during its life cycle and turned into oxygen and 
carbon. Using non-renewable energy sources (coal, fuel oil, gas), unlike energy sources based on wood, much larger amount 
of CO

2

 is released to the air. It builds up over the years and contributes to enhancing the greenhouse effect. The principle of 

clean combustion meets all requirements of preserving the environment, and Alfa Plam has devoted all its development and 
activities to fulfilling this goal. 

 CAUTION 

 

-

 

The minimum installed power of the heating system must not be less than 65% of the boiler’s rated of the boiler,  and 

the maximum power of the system must not exceed 100% of the boiler’s rated power. 

-The flue connected to the boiler must meet the requirements set in the user manual. 
-To connect the appliance to the flue, do not use flexible hoses instead of flue pipes.  
- Regular maintenance and care, such as cleaning the boiler, flue pipes and nozzles (pipes), are important for safe 

operation, and especially for effectiveness and maintenance value of the boiler. 
- Do not perform any unauthorized modification to the appliance, as any unauthorized modification will void the warranty. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание Grande 37 Lux

Страница 1: ...37 Lux Instruction for use maintenance and installation This product meets the requirements of the Ecodesign Directive in terms of efficiency and air pollution level in order to contribute to the red...

Страница 2: ...by a person authorized by Alfa Plam The flame that develops in the boiler during normal combustion of wood biomass releases just the amount of carbon dioxide CO2 that would be released by natural wood...

Страница 3: ...CE 10 8 IMPORTANT SAFETY INFORMATION 11 9 PELLET QUALITY IS VERY IMPORTANT 11 9 1 PELLET STORAGE 11 10 BOILER CONTROL SYSTEM 11 10 1 Electrical connection diagram 12 10 2 Touch screen control panel di...

Страница 4: ...ents and or damage occurred due to use of non original or inappropriate spare parts Installations is solely within the responsibility of the installer 2 1 MAIN USER RESPONSIBILITIES The boiler user mu...

Страница 5: ...ommissioning inspect the operation during at least 30 minutes in order to check whether all requirements have been met After finishing the installation the installer should provide the customer with t...

Страница 6: ...the 80 mm flue pipe Therefore make sure that the flue pipe is completely sealed Carefully analyze the position and condition of the space through which the flue passes If the flue pipe passes through...

Страница 7: ...ent always turned upward Figure 4 We recommend not making long horizontal sections for the flue connection If there is no other possibility the flue pipes should not have a downward slope but upward t...

Страница 8: ...7 AISI 316 steel flue with double insulated chamber material resistant to 400 C Optimal efficiency 100 Waterproof flue with double insulated chamber and outer casing of light concrete Optimal efficien...

Страница 9: ...ng devices such as a hoods hair dryers fans etc located in the room with the boiler combustion air fresh air must be supplied from outside In any case this should be discussed with the competent chimn...

Страница 10: ...e universal ones Check if the valve is easily opened check with a finger so that it could be opened with the pump s power The non return valve is placed behind each pump If there are multiple pumps yo...

Страница 11: ...nting damage due to sudden failure of a component which may seriously endanger the safety of persons and or your property Clean the firebox and the space underneath it when cleaning the ashes 6 2 SAFE...

Страница 12: ...to the following safety rules Turn the pellet boiler off before beginning any procedure Make sure that the ash is cold before beginning any procedure on the boiler Vacuum the ashes deposited in the c...

Страница 13: ...ONS ENSURE THE MAXIMUM OUTPUT OF THE BOILER AND THE TEMPERATURE OF THE SYSTEM Make sure that the pellet boiler and ashes are cold For complete weekly cleaning or after 200 kg of used pellets whichever...

Страница 14: ...he type and quality of the pellets The manufacturer is not in any way responsible for poor performance of the boiler due to the use of poor quality pellets If sawdust or small decomposed pellets are p...

Страница 15: ...isplay 1 2 Start screen display 2 2 YELLOW GREEN POWER CABLE FLUE GAS FAN TURBULATOR REDUCER PRIMARY AIR FAN LIGTER AUGER REDUCER THERMOMETER MANOMETER PENDULUM REDUCER PUMP MICRO SWITCH 1 MICRO SWITC...

Страница 16: ...Auger Auger on off Pump Pump on off Valve Pendulum reducer on off V2 Room fan on off V3 Turbulator reducer on off A1 Heater igniter on off A3 Pendulum reducer on off A5 Auger reducer blocked not bloc...

Страница 17: ...ition failure Er15 Power outage longer than 50 minutes Er16 Communication error RS485 Er17 Airflow regulator error Er18 No pellet Er25 Firebox cleaning motor error Er26 Turbulator cleaning motor error...

Страница 18: ...es Boiler Thermostat The adjustable boiler water temperature range is from 40 C to 80 C By setting the temperature of the water in the boiler the user sets the operating condition of the boiler i e th...

Страница 19: ...the steps decreases and increases the calibrated auger speed Fan Calibration menu for changing the speed of the flue gas fan The system has 15 calibration steps from 7 to 7 the factory setting is 0 Th...

Страница 20: ...s is performed during the check up phase During this phase the flue gases motor is working at maximum speed while the auger and the igniter are turned off The check up phase takes a few seconds and th...

Страница 21: ...ases temperature exceeds 230 C or when the boiler water temperature reaches 85 C During this phase the pellet feed stops until the flue gases temperature is below 230 C or the water temperature in the...

Страница 22: ...ck error Internal clock problems Turn the appliance off and then on in the ON OFF menu Check the accuracy of the set time Insufficient internal battery capacity Check the accuracy of the chrono mode p...

Страница 23: ...t and cleanliness Contact the service NOTE If the recommended solution fails to remove the direct cause of the alarm CONTACT ALFA PLAM CALL CENTER or the closest authorized service 11 INFORMATION ON B...

Страница 24: ...8 Flue gas temperature value at reduced power C 70 Mean NOx value at 10 O2 at rated power mg m3 191 Mean CO value at 10 O2 at rated power mg m3 26 Mean dust emission value at 10 O2 at rated power mg m...

Страница 25: ...d floor heating Note If only floor heating is connected to the boiler make sure to install an accumulation tank BUFFER Legend 1 Pellet boiler 2 Air vent 3 Safety valve 3 bar 4 Three way mixing valve w...

Страница 26: ...draulic installation diagram accumulation tank Legend 1 Pellet boiler 2 Air vent 3 Safety valve 3 bar 4 Air vent 5 Circulation pump 6 Three way mixing valve with pipe thermostat 7 Accumulation tank BU...