3 Operation
Study the instructions carefully and pay special attention to the warnings!
Ensure that the Steam Generator operates smoothly.
The items refer to the parts list and service kits section.
Step 5
1. Activate the gun by pulling the inner handle (G). Slide the pawl
(H) forwards to ensure that handle can hold it’s self.
2. Steam the sampling valve for 2 minutes.
NB: make sure that steam is present at the steam outlet (P1)
on the pressure relief valve (P) doing the 2-minutes steaming.
3. Shut the gun off by sliding back the pawl (H).
P
2900-0145
P2
P1
G
H
Step 6
1. Turn off the gas valve (D).
2. Release the enclosed steam by pulling the handle (P2) on the
Pressure relief valve (P).
3. Remove the gun from the non-return valve. The sampling valve
is now sterilised and ready to take a representative sample.
Note:
the tank cap cannot be opened until all the pressure in the tank
has been released.
2900-0146
D
P2
P
9