3 Operation
Study the instructions carefully and pay special attention to the warnings!
Ensure that the Steam Generator operates smoothly.
The items refer to the parts list and service kits section.
3.1
Operation
Step 1
Always read the technical data thoroughly.
See chapter 5 Technical data
CAUTION
Alfa Laval cannot be held responsible for incorrect operation.
Never touch the Steam Generator or the pipelines when
processing hot liquids or when sterilising.
Attention:
Before using the Steam Generator, it is essential that a non-return
valve* (N) and a pressure relief valve* (P) are mounted on the
sampling valve to ensure proper sterilisation.
*= not included in this package
N: Non-return valve
- Sizes 4 and 10: 9614-1955-01
- Size 25: 9614-1955-04
C: Clamp ring
- Sizes 4 and 10: 211290
- Size 25: 211053
S: Clamp seal
- Sizes 4 and 10: 290273
- Size 25: 9611-99-2012
P: Pressure relief valve
- Sizes 4 and 10: 9614-1957-01
- Size 25: 9614-1957-02
P1: Steam outlet
P2: Quick release of steam
C
P
P2
P1
N
S
2900-0141
Step 2
1. Make sure that the sampling valve is in closed position (single
seat) or in steam position (double seat), before steaming
2. Pull the front handle (A) forwards and mount the steam
generator pistol on the non-return valve (B).
Note: do not activate the handle (G) yet.
2900-0142
B
A
G
7