background image

4 Installation

4.4

Operating LED feedback

Actuator

Actuator

Actuator status

status

status

LED

LED

LED feedback

feedback

feedback

De-energised

Green

Energised

Yellow

Alarm (Air pressure)

Red flashing

11

Содержание ThinkTop D30

Страница 1: ...Patented Sensor System Registered Design Registered Trademark ESE02248 EN6 2022 10 Original manual Instruction Manual ThinkTop D30...

Страница 2: ......

Страница 3: ...Important information 6 2 2 Warning signs 6 2 3 Safety precautions 6 3 General information 7 3 1 Concept 7 3 2 Working principle 7 3 3 Recycling information 7 4 Installation 8 4 1 Product dimensions...

Страница 4: ...or Valve Control and Indication Designation ThinkTop D30 Type is in conformity with the following directives with amendments EMC Directive 2014 30 EU RoHS Directive 2011 65 EU and amendments The perso...

Страница 5: ...or Valve Control and Indication Designation ThinkTop D30 Type is in conformity with the following directives with amendments The Electromagnetic Compatibility Regulations 2016 The Restriction of the U...

Страница 6: ...Installation Always Always Always read the technical data thoroughly Never Never Never install the ThinkTop D30 before the valve or relay is in a safe position If welding close to the ThinkTop D30 Al...

Страница 7: ...oid valve allows control of the processing valve Mounted on top of the valve the unit receives signals from a PLC system to control the solenoid valve and it returns the supervised air pressure signal...

Страница 8: ...Koltek Yes LKLA T Yes LKLA No ARC Yes SRC Yes SRC long stroke No i SSV Yes Unique SSV Yes Unique SSV long stroke No Unique SSV DN125 DN150 No SSV DN80 76 1 mm High pressure No SSV DN100 101 6 mm High...

Страница 9: ...arked with EX Step Step Step 2 2 2 Connect the air supply to the air in port A Connect the air out port B to the actuator NOTE NOTE NOTE Option in case of a air supply hose system Connect the air supp...

Страница 10: ...nit must be supplied by an isolating source that complies with the requirements for class 2 power units UL1310 or class 2 and 3 transformers UL1585 Electrical Electrical Electrical connection connecti...

Страница 11: ...4 Installation 4 4 Operating LED feedback Actuator Actuator Actuator status status status LED LED LED feedback feedback feedback De energised Green Energised Yellow Alarm Air pressure Red flashing 11...

Страница 12: ...ios scenarios scenarios Condition Condition Condition Possible Possible Possible cause cause cause Solution Solution Solution Red LED flashing Insufficient air pressure in the actuator Check the air s...

Страница 13: ...active 39 mA Current consumption solenoid inactive 28 mA Short circuit and brownout protection Yes EN61131 2 Solenoid Solenoid Solenoid valve valve valve Type of solenoid 3 2 NC Number of solenoids 1...

Страница 14: ...7 Parts list 7 1 Parts list 14...