![Alfa Laval TE75P231 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/alfa-laval/te75p231/te75p231_manual_2895081048.webp)
Page 46
Instruction Manual, SSB Retractor - Mini Retract-A-Ball
Standard machines and machines delivered with ATEX certification
in accordance with Directive 94/9/EC
IM-TE91A901-EN1
Re-Build & fitment of New Service Repair Kit
(continued)
23.
Fitting the Home Chamber Spigot Seal Part No. TE75P538 (EPDM) or TE75P508 (Isolast)
Carefully fit the O-ring in the O-ring groove at the front of the Home Chamber.
See Figure 46.
24.
Test the Unit after Re-build.
Lay the Unit on the bench. Connect an air supply to the Air Connector fitted to the Inlet Adaptor.
Apply a pressure of 4 Bar to open the SSB Retractor. Release the pressure & ensure the unit
closes fully on the return spring.
Extend the unit again with 4 Bar pressure & close off the air supply so that the unit is held in the
open position.
Measure the length of the extension with a ruler & leave the unit for half an hour. Re-measure
to ensure there has been no movement which would indicate a leak in the air seals.
Figure 46
Figure 47