4 Installation
4.1
Unpacking, handling and storage
Step 1
Refer to the pump weights guide (6 Technical data) before selecting and using any lifting gear. The drawings show how
the pump should be lifted.
Ensure that lifting equipment is correctly rated and used within these limits.
Pump with drive unit
Bareshaft pump
Step 2
On receipt always:
-
Check the delivery note against the goods received.
-
If motorised, check that the drive instructions are available.
-
Be careful not to discard any manuals that may be enclosed with the packaging.
-
Inspect the packing for signs of damage in transit.
-
Carefully remove the packing away from the pump.
-
Inspect the pump for any visible signs of damage.
-
Clean away the packing from the pump port connections.
-
Report any damage immediately to the carrier.
Step 3
After receipt and inspection, if the pump is not to be installed immediately, the pump should be repacked and placed in
suitable storage. The following points should be noted:
-
Plastic or gasket type port covers should be left in place.
-
Pumps received wrapped with corrosion inhibiting treatment material should have wrapping replaced.
-
A clean, dry storage location free from vibration should be selected. If a moist or dusty atmosphere is used for storage,
further protect the pump or unit with a suitable cover.
-
Rotate the pump/pump unit by hand weekly, to prevent bearing damage.
-
All associated ancillary equipment should be treated similarly.