![Alfa Laval SRU series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/alfa-laval/sru-series/sru-series_instruction-manual_2895192010.webp)
4 Installation
To ensure optimum operation it is important that any pump unit is installed correctly. When designing a pumping system the
following should be taken into consideration.
Table of Maximum Forces and Moments
Forces
Moments
Pump
Model
Units
FZ
FY
FX
EF
Units
MZ
MY
MX
EM
N
80
60
70
120
Nm
75
90
115
165
SRU1
lbf
18
13
16
27
lbft
55
66
85
122
N
125
100
110
195
Nm
90
105
130
190
SRU2
lbf
28
22
25
44
lbft
66
77
96
140
N
165
135
150
260
Nm
100
115
140
205
SRU3/4
lbf
37
30
34
58
lbft
74
85
103
151
N
300
250
250
460
Nm
125
145
175
260
SRU5/6
lbf
67
56
56
103
lbft
92
107
129
192
Direction of flow:
The direction of flow is dictated by the direction of rotation of the drive shaft. Reversing the direction of rotation will reverse the
flow direction.
Suction
Discharge
Discharge
Suction
Discharge
Suction
Suction
Discharge
10