Alfa Laval Mini City
Installation and operating
13
EN
Room thermostat T87C2073
3
1
LCD display
2
Dial
3
Right touch button
4
Left touch button
Control modes
3.1
The room thermostat has five different control modes to select between; the default mode
is Outside Temperature Control (OTC control).
1.
Room temperature control
Supply setpoint is calculated based on the room temperature setpoint and the
actual room temperature.
2.
OTC control;
Require a connected outdoor temperature sensor.
Supply setpoint is purely based on the outside temperature.
3.
OTC control with room temperature compensation;
Require a connected outdoor temperature sensor.
Supply setpoint is based on the outside and room temperature.
4.
Constant supply temperature with Heat demand input
Select a fixed supply temperature setpoint. This setpoint is always active.
NOTE
: Does not work with an outdoor thermostat connected.
5.
Constant supply temperature
Select a fixed supply temperature setpoint. This setpoint is always active.
NOTE
: Does not work with an outdoor thermostat connected.
Changing the control mode
3.2
1)
Turn the dial down to 10°C.
2)
Enter the setting menu by pressing both right and left touch button for 10 seconds.
3)
Use the dial to choose control mode, 1-5.
Wait a few seconds and the room thermostat automatically leaves the setting menu.
4)
Restart the room thermostat after changing the control mode.