3 Installation
Study the instructions carefully and pay special attention to the warnings! Always check the pump before operation.
- See pre-use check in section 3.3 Pre-use check.
3.2
Installation
Step 1
!
Always read the technical data thoroughly. (See chaper 6 Technical data)
Always have the pump electrically connected by authorised personnel. (see the motor instructions).
CAUTION
Alfa Laval cannot be held responsible for incorrect installation.
WARNING:
Alfa Laval recommends the installation of lockable repair breaker. If the repair breaker is to be used as an emergency stop,
the colours of the repair breaker must be red and yellow.
Caution:
The pump does not prevent back flow when intentionally or unintentionally stopped. If back flow can cause any hazardous
situations, precautions must be taken e.g. check valve to be installed in the system preventing that described above.
Note
In case of shaft seal leakage, the media will drip from the slot in the bottom of the adaptor. In case of shaft seal leakage, Alfa
Laval recommends placing a drip tray underneath the slot to collect the leakage.
Step 2
Ensure that there is sufficient clearance around the pump.
Step 3
Check that the flow direction is correct.
Step 4
1. Ensure that the pipelines are routed correctly.
2. Ensure that the connections are tight.
Remember seal rings!
TD202-037_1
Few bends
Correct!
8