20
It is important to observe the technical data during installation, operation and maintenance.
Inform the personnel about the technical data.
5. Technical Data
5.1 Technical Data
Data
Max. product pressure
1000 kPa (10 bar)
(145 psi)
Min. product pressure
No vacuum
Temperature range
-10
0
C to +95
0
C
(14°F to 203°F)
Temperature range (with upper diaphragm inPTFE/EPDM)
-10
0
C to +140
0
C
(14°F to 284°F) (higher on request)
Air pressure
0 to 600 kPa (0 to 6 bar)
(0 to 87 psi)
Flow range Kv
(Lv), fully open (
∆
p = 1bar)
(14.5 psi)
Approx. 23m
3
/h
(101 gal/m)
Flow range Kv
(Lv), low capacity (
∆
p = 1bar)
(14.5 psi)
Approx. 2m
3
/h
(8.8 gal/m)
(Alternative size)
(regulating area)
Approx. 15m
3
/h
(66 gal/m)
(CIP area)
Materials
Product wetted steel parts
AISI 316 L
Other steel parts
AISI 304
Upper diaphragm
Nitrile (NBR), (standard)
Lower diaphragm
PTFE covered EPDM rubber, (standard)
Alternative upper diaphragm
EPDM/PTFE, (for temperatures 95-140
o
C)
(203°F to 284°F)
Alternative upper diaphragm
Solid Teflon (PTFE), (for temperatures above 140
o
C)
(284°F)
Alternative lower diaphragm
Solid Teflon (PTFE), (for temperatures above 140
o
C)
(284°F)
O-ring Nitrile (NBR), (standard)
Alternative O-ring
Viton (FPM), (for temperatures above 95
o
C)
(203°F)
Finish
Semi bright
Noise
One meter away from - and 1.6 meter above the exhaust the noise level of a valve actuator will be approximately 77db(A)
without noise damper and approximately 72 db(A) with damper - Measured at 7 bars air-pressure.