4 Operation
Study the instructions carefully and pay special attention to warnings! Always check the Agitator before operation. Alfa Laval
recommends a soft starter for the Agitator to reduce the load on tank and Agitator.
All position numbers and item numbers refer to the drawings shown and specified in chapter 7 Parts list/Service kits.
NOTE
The Agitator must not be run at temperatures above 90°C.
Ensure that all surfaces in contact with product are totally clean so product is not contaminated and that the Agitator itself is
not exposed pit corrosion.
Pay special attention to:
-
Impeller device surfaces.
-
Surfaces between propellers and shaft.
-
Surfaces around sealing and bushings.
-
Surfaces around weldings.
4.5.2 Cleaning examples
-
CIP fluids to be connected to CIP connection (27 and 28) if with Aeration and (27) only if without Aeration.
-
Pre-rinse with cold water for approximately 3-5 minutes.
-
The caustic cleaning step should be made with hot caustic 60-70°C 30 - 45 minutes.
-
The yeast mixer should be running continuously during CIP.
-
The recommended CIP flows versus pressures can be calculated from the formula in section 6.1 ALT-SB-15, With Aeration
(item number 9614322301) and 6.2 ALT-SB-15, Without Aeration (item number 9614328901).
-
The cleaning should be made as soon as possible after emptying the tank, while the inside surfaces are still wet.
-
Final-rinse with hot water for approximately 3 minutes followed by cold water for 3-5 minutes or until last rinsing water is
free from chemicals.
19
Содержание ALT-SB-15
Страница 1: ...100000242 EN3 2020 05 Original manual Instruction Manual ALT SB 15...
Страница 2: ......