Installation
Mounting
It is recommended to mount the plate heat exchanger on the
fl
oor, on feet or on the wall.
Larger heat exchangers should be secured with support
mountings (ordered as accessory) intended for a speci
fi
c heat
exchanger, or be secured with straps or by means of mounting
bolts.
Note!
Regardless of the mounting method minimize the
pipe loads at installation.
Maximum tightening torques for the mounting bolts according
to table below.
Bolt dimension
Torque
Nm
lbf*ft
M5
2.3
1.7
M6
3.8
2.8
M8
9.5
7.0
M8 (Extra small units)
8.0
5.9
M10
19.0
14.0
M12
33.0
24.3
UNC 1/4”
3.8
2.8
UNC 5/16”
8.6
6.4
UNC 3/8”
15.6
11.5
In a rigid pipe system, small heat exchangers can be
suspended directly in the pipework. To avoid vibrations, use
anti-vibration mounting according to picture below.