Alfa IN PEGAS 60 PLASMA Скачать руководство пользователя страница 4

 

4/19 

ALFA IN a.s © 

 

 

 

 

 

 

                 

www.alfain.eu

 

3

 

2.  SAFETY INSTRUCTIONS AND WARNINGS 

1.  OPERATION AND MAINTENANCE OF PLASMA ARC EQUIPMENT CAN 

BE DANGEROUS AND HAZARDOUS TO YOUR HEALTH. 

2.  Plasma arc cutting produces intense electric and magnetic emissions that 

may interfere with the proper function of cardiac pacemakers, hearing aids, 
or other electronic health equipment. Persons who work near plasma arc  
cutting applications should consult their medical health professional and the 
manufacturer of the health equipment to determine whether a hazard exists. 

3.  Once the packing has been opened, make sure that the machine is not 

damaged. If in any doubt, call the service centre. 

4.  This equipment must only be used by qualified personnel.  
5.  During installation, any electric work must only be carried out by trained 

personnel. 

6.  The machine must be used in a dry place with good ventilation. 
7.  Make sure that no metal dust can be drawn in by the fan inside the 

machine, as this could cause damage to the electronic circuits. 

8.  It is prohibited to connect more than one INVERTER generator in series or 

in parallel. 

9.  When installing the machine, follow the local regulations on safety. 
10.  The position of the machine must allow easy access by the operator to 

the controls and connectors. 

11.  When the cutting machine is operating, all its covers and doors must be 

closed and well fixed. 

12.  Do not expose the cutting machine to direct sunlight or to heavy rain. 

This equipment conforms to protection rating IP 23 S. 

13.  The operator must wear gloves, clothes, shoes, and a helmet or a 

welder’s helmet, which protect and are fire-resistant in order to protect him 
against electric shock, flashes and sparks from cutting. 

14.  The operator must protect his eyes with safety visor or mask designed for 

welding, fitted with standard safety filters. He should also be aware that 
during plasma cutting ULTRAVIOLET RADIATION is emitted. Therefore it is 
vital that his face is also protected from radiation. Ultraviolet rays produce 
the same harmful effect as sun burning on unprotected skin.  

15.  The operator is obliged to warn anyone near the cutting area of the risks 

that cutting involves and to arrange to provide adequate protection 
equipment. 

16.  Keep all fumes and gases from the breathing area. 
17.  Keep your head out of the fume plume. 
18.  Use an air-supplied respirator if ventilation is not adequate to remove all 

fumes and gases. 

19.  The kinds of fumes and gases from the plasma arc depend on the kind of 

metal being used, coatings on the metal, and the different processes. You 
must be very careful when cutting or welding any metals which may contain 

Содержание PEGAS 60 PLASMA

Страница 1: ...ALFA IN a s www alfain eu PEGAS 60 PLASMA MANUAL EN 04 PLASMA CUTTING MACHINE PEGAS 60 PLASMA OPERATING MANUAL...

Страница 2: ...NT 1 INTRODUCTION 3 2 SAFETY INSTRUCTIONS AND WARNINGS 4 3 CONDITIONS OF USE 7 4 TECHNICAL DATA 8 5 MAIN PARTS OF THE MACHINE 9 6 ACCESSORIES 11 7 GETTING STARTED 13 8 CUTTING 15 9 MAINTENANCE 17 10 S...

Страница 3: ...before installing operating or servicing the equipment While the information contained in this Manual represents the Manufacturer s best judgement the Manufacturer assumes no liability for its use Mac...

Страница 4: ...sy access by the operator to the controls and connectors 11 When the cutting machine is operating all its covers and doors must be closed and well fixed 12 Do not expose the cutting machine to direct...

Страница 5: ...ble materials are removed from the work area to avoid any risk of fire 26 The operator must NEVER cut containers that have previously contained petrol lubricants gas or similar flammable materials eve...

Страница 6: ...ith increased protection for the operator DC current 141V peak value AC current 141V peak value and 100V effective 4 Plasma cutting DC current 500V peak value 32 In case 1 the dc machines with rectifi...

Страница 7: ...F USE 1 This equipment must only be used by qualified personnel 2 During installation any electric work must only be carried out by trained personnel 3 Device complies with IEC 61000 3 12 with followi...

Страница 8: ...ell as the radiated interference During operation the device may be the source of interference Caution We warn users that they are responsible for possible interference from welding 4 TECHNICAL DATA M...

Страница 9: ...Description A1 Quick connector earthing cable A2 Connector remote control in standard doesn t work only on request A3 Connector torch A4 Potenciometer set cut current A5 LED indicator when illuminate...

Страница 10: ...dicator arc burning after you press the torch button it shines on the torch is a voltage A9 Switch Setting of gas flow Continuous cutting Cutting material with gaps Caution Higher wear of nozzles and...

Страница 11: ...5302 Air Filter AT 1000 5304 Adapter for AT 1000 PEGAS PLASMA S777a Welding Helmet ALFA IN S777a Black SCP120 6 60 Torch Plasma SCP 120 6m PEGAS 60 5864 Set START to the torch SCP 120 PEGAS 60 Recomm...

Страница 12: ...CP 120 6 SCP1206 Swirl Ring 6 Holes 80 120A 7 SCP1207 Swirl Ring 4 Holes 30 70A 9 SCP1220 10 Cutting Tip 1 0 40 50A 9 SCP1220 11 Cutting Tip 1 1 50 60A 9 SCP1220 12 Cutting Tip 1 2 60 70A 10 SCP1222 0...

Страница 13: ...aterial being cut and to the connector A1 10 Check up the input air pressure min 5 bar max 8 5 bar and make a regulation if necessary 11 Set potentiometer A4 to the cutting power you need 12 Fit the t...

Страница 14: ...pressure air is permitted That could damage the plasma machine and the cutting torch OPTIONAL AIR FILTERS To achieve high quality cutting and to avoid serious disturbances to the torch it is highly ad...

Страница 15: ...eve a good cutting quality make sure the distance between the tip and the material is about 3 5 mm The Stand Off Guide located at the end of the plasma torch guarantees the distance At a greater dista...

Страница 16: ...e machine from the mains before any intervention inside the machine 7 PEGAS 60 PLASMA is adapted for use with torch Plasma SCP 120 PEGAS 60 This combination comply with EN 60974 7 Article 10 1 4 Using...

Страница 17: ...diffuser has a negative impact on the quality of cutting and causes very strong interference that may cause the collapse of the machine control electronics or influence the surrounding devices If the...

Страница 18: ...or components that fail due to defects in material or workmanship within the warranty period The warranty period begins on the date of sale to the end user 4 If warranty is being sought please contac...

Страница 19: ...d waste material In accordance with European Council Directive 2002 96 EC on electrical and electronic equipment waste and its implementation in accordance with national law electric tools that have r...

Отзывы: