![Alfa IN PEGAS 60 PLASMA Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/alfa-in/pegas-60-plasma/pegas-60-plasma_operating-manual_2894909013.webp)
13/19
ALFA IN a.s ©
www.alfain.eu
3
7. GETTING STARTED
Getting started must be consistent with technical data and conditions of use
(especially with 3. point).
FIRST STEPS
NOTE
This equipment must only be used by qualified personnel.
1. Before beginning work is necessary to connect the machine to the mains.
2. Check completeness of the mounted cutting torch.
3. Connect the torch to the connector. By means of the thorn (part of the
delivery) press the safety pin. Turn the nut of the connecter clock wise and
tight it properly.
4. Connect the mains cable
A13
to the on the network according 4
TECHNICAL DATA
5. Connect the compressed air on connector
A11
on the rear wall of the
machine.
6. Set the air pressure by means of regulator
A12
and manometer
A10
to 5
bars.
7. Connect the mains plug to the mains socket.
8. After turning on the ON/OFF switch
A14
the display
A5
will illuminate.
9. Connect the work lead cable to the material being cut and to the
connector
A1
.
10. Check up the input air pressure (min 5 bar, max 8,5 bar) and make a
regulation if necessary.
11. Set potentiometer
A4
to the cutting power you need.
12.
Fit the torch with appropriate type of cutting tip electrode and shield
cup according to the selected cutting current.
13.
Press the trigger on the cutting torch, the pre gas will flow for 1 s.
14.
The pilot arc will start.
15.
Shift the torch with the pilot arc close to the material, the pilot arc will
change to cutting arc automatically. If you do not start cutting within 2 s,
the arc will snuff off. If the torch delays during the cutting from the
material, the arc will snuff off. In case that the machine is in mode Cutting
material with gaps – switch
A9
position
, cutting arc will change to pilot
arc and if you
do not start cutting within 2 s, this arc will snuff off.
16.
To finish the cutting process, release the torch trigger.
REQUIREMENTS
FOR SOURCE OF COMPRESSED AIR
1. Delivered air pressure must be max. 8,5 bar and min. 5 bar.
2. Air consumption minimal 220 l/min
3.
Compressed air for the plasma must be clean and dry.