background image

- 9 - 

ALFA IN a.s. ©        

 

 

 

 

 

 

 

www.alfain.eu

 

A6 

LED – ARC FORCE function is selected 

A7 

LED – MMA method is selected 

A8 

LED – MMA VRD method is selected 

A9 

LED – TIG method is selected 

A10 

Display 

A11 

LED of turning on the machine 

A12 

LED overheating 
(When illuminated leave the machine turned on and wait until the 
machine cools down.) 

A13 

Encoder 

A14 

Quick connector (+) 

A15 

Mains cable 

A16 

Main switch 

 

Overheating of the machine –

 LED ALARM lights up and the machine switches 

to the mode, when is effectively cooled to the operating temperature. Don’t use 
the  machine  for  about  15  minutes.  Until  the  machine  reaches  the  operating 
temperature, it remains in „cooling mode“ and the machine will only be able to 
supply reduced welding current. 
 

HOT START

 

 Function HOT START is designed for easier arc ignition. 

 

ARC FORCE

 

 Function ARC FORCE is the prevention against the unwanted 

sticking  of  the  electrode  to  the  weldment  and  against  the  unwanted  arc 
extinguishing. 
ARC FORCE is off – it is used at medium and higher welding currents.  
Maximal ARC FORCE - it is used if you weld with low currents (vertically up, over 
the head, etc.). 
Increased ARC FORCE – it is used for easier arc ignition and arc maintaining, 
for good penetration. 
When welding thin sheets, ARC FORCE increases the risk of burning.  
 

MMA VRD 

– Voltage Reduction Device. If this mode is active and when 

the welding process is finished the VRD immediately reduces the open-circuit 
voltage to 14 V. Inverters PEGAS 400 E CEL generate the open-circuit voltage 
95  V  (MMA)  and  14  V  (TIG)  and  inverters  PEGAS  500  E  generate  the  open- 
circuit  voltage  90  V,  which  is  safe  and  is  in  compliance  with  the  standard  EN 
60974-1. However, in a certain environment the welder can feel very unpleasant 
tingling – electrical shocks. If the MMA VRD mode is active, it will not exposure 
the welders to those unpleasant states.  

 

Содержание PEGAS 400 E CEL

Страница 1: ...ALFA IN a s www alfain eu PEGAS 400 500 E CEL manual EN 01 WELDING MACHINES PEGAS 400 E CEL PEGAS 500 E OPERATING MANUAL ...

Страница 2: ...u CONTENT 1 INTRODUCTION 3 2 SAFETY PRECAUTIONS 4 3 OPERATING CONDITIONS 5 4 TECHNICAL DATA 6 5 EQUIPMENT 7 6 OPERATOR CONTROLS 8 7 GETTING STARTED 10 8 ROUTINE MAINTENANCE INSPECTION 12 9 STATEMENT OF WARRANTY 12 10 DISPOSAL 13 ...

Страница 3: ...chine may be operated only by trained persons and only in the technical provisions Company ALFA IN a s accept no responsibility for damage caused by improper use Before commissioning please read carefully this manual The machine complies with the appropriate CE mark For maintenance and repairs use only original spare parts There is of course a complex of our services We reserve the law of adjustme...

Страница 4: ...During welding especially in small spaces it is necessary to ensure an adequate supply of fresh air because during welding harmful fumes arise 5 In tanks of gas oil fuel etc even empty ones do not make welding because there is a chance of explosion 6 In areas with chance of explosion special provisions are applied 7 Welding machines that are subjected to great exertion must comply with specific se...

Страница 5: ...zed officer according to ČSN 331500 and ČSN 050630 see Maintenance and service tests 6 All interventions in the el equipment as well as repair removal of the plug fuse replacement should be performed by an authorized person 7 Welding machine is from the factory set at 400V with tolerance range of 13 which allows operation of the device in mains 380V 8 With competent mains voltage and input must ma...

Страница 6: ...We warn users that they are responsible for possible interference from welding 4 TECHNICAL DATA PEGAS 400 E CEL Method MMA TIG Mains voltage V Hz 3x400 50 60 Welding current range A 20 400 20 400 Open circuit voltage U20 V 95 0 14 0 14 0 Mains protection A 25 Max effective current I1eff A 24 6 18 9 Welding current DC 100 I2 A 310 310 Welding current DC 60 I2 A 400 400 Welding current DC x I2 A 60 ...

Страница 7: ... with an increased risk of electric shock The machine structure is designed so that in any case even if the failure rectifier does not exceed the permitted peak value of the open circuit voltage according to EN 60974 1 i e 113 V direct current or 68 V alternating 5 EQUIPMENT ACCESSORIES TO ORDER Item No Description Picture VM0025 Earthing cable 3 m 500 A 70 mm2 VM0185 Cable with E holder 3 m 400 A...

Страница 8: ...g Helmet S9B Shooting Blue Shark 6 OPERATOR CONTROLS Fig 1 Main parts Pos Description A1 Quick connector A2 Connector for remote control A3 Welding method switch MMA electrode MMA VRD TIG A4 LED HOT START function is selected A5 LED values in A ...

Страница 9: ...E is the prevention against the unwanted sticking of the electrode to the weldment and against the unwanted arc extinguishing ARC FORCE is off it is used at medium and higher welding currents Maximal ARC FORCE it is used if you weld with low currents vertically up over the head etc Increased ARC FORCE it is used for easier arc ignition and arc maintaining for good penetration When welding thin she...

Страница 10: ... the position ON 3 Connect the electrode holder to the quick connector A14 and the earthing cable to the quick connector A1 according the instruction on the electrodes packing 4 By means of the button A3 switch to the position MMA or MMA 5 By means of the encoder A13 set the welding current LED A5 will shine 6 Press and then rotate the encoder A13 to adjusting the level of HOT START and ARC FORCE ...

Страница 11: ...cket 50 60 Hz The supply fuses or circuit breaker should correspond to the technical data stated in this manual 2 Switch the main switch A16 to the position ON 3 Connect the TIG torch to the quick connector A1 4 Connect the earthing cable to the quick connector A14 5 By means of the button A3 switch to the position TIG 6 Connect the gas hose to the gas cylinder connector on the gas bottle 7 By mea...

Страница 12: ...uitably qualified or competent person 7 A competent person must be a person who has acquired through training qualification or experience or a combination of them the knowledge and skills enabling that person to safely carry out a risk assessment and repairs to the electrical equipment in question 8 The person carrying out the servicing needs and repairs must know what to look at what to look for ...

Страница 13: ...nual 6 Within this operating manual are details regarding the maintenance necessary to ensure trouble free operation 7 NOTE Warranty repairs must be performed by either an ALFA IN Service Centre an ALFA IN distributor or an Authorised Service Agent approved by the company ALFA IN 8 As a warranty list serves proof of purchase invoice on which is the serial number of the machine 10 DISPOSAL Only for...

Отзывы: