- 10 -
ALFA IN a.s. ©
www.alfain.eu
7. GETTING STARTED
Getting started must be consistent with technical data and conditions of use.
GETTING STARTED MMA – COATED ELECTRODE
Fig. 2 – Getting started MMA
1. Insert the mains plug into a suitable 3x400 V mains socket, 50-60 Hz. The
supply fuses or circuit breaker should correspond to the technical data
stated in this manual.
2. Switch the main switch
A16
to the position “ON“.
3. Connect the electrode holder to the quick connector (+)
A14
and the
earthing cable to the quick connector (-)
A1
according the instruction on
the electrodes packing.
4. By means of the button
A3
switch to the position MMA
or MMA
.
5. By means of the encoder
A13
set the welding current. LED
A5
will shine.
6. Press and then rotate the encoder
A13
to adjusting the level of HOT
START and ARC FORCE. The appropriate LED
A4
or
A6
will shine.
NOTE
Prevent touching the electrode any metal material for in this mode
the quick connectors
A14
and
A1
are under current. Insert the coated electrode