background image

-4- 

 

ALFA IN a.s. ©   

 

   

 

 

 

 

 

www.alfain.eu

 

 

 

 

When installing the machine, follow the local regulations on safety. 

 

The position of the machine must allow easy access by the operator to the 
controls and connectors. 

 

When the welding machine is operating, all its covers and doors must be 
closed and well fixed. 

 

Do not expose the welding machine to direct sunlight or to heavy rain. This 
equipment conforms to protection rating IP23S. 

 

During welding, the welding cables must be located near or at ground level. 
They should be as short as possible. 

 

The operator must wear gloves, clothes, shoes, and a helmet or a welder’s 
helmet, which protect and are fire-resistant in order to protect him against 
electric shock, flashes and sparks from welding. 

 

The operator must protect his eyes with safety visor or mask designed for 
welding, fitted with standard safety filters. He should also be aware that 
during electrical welding ULTRAVIOLET RADIATION is emitted. Therefore 
it is vital that his face is also protected from radiation. Ultraviolet rays 
produce the same harmful effect as sun burning on unprotected skin.  

 

The operator is obliged to warn anyone near the welding area of the risks 
that welding involves and to arrange to provide adequate protection 
equipment. 

 

It is very important to arrange for sufficient ventilation, especially when 
welding in enclosed spaces. We suggest using suitable fume extractors to 
prevent the risk of intoxication by fumes or gas generated by the welding 
process. 

 

The operator must ensure all flammable materials are removed from the 
work area to avoid any risk of fire. 

 

The operator must NEVER weld containers that have previously contained 
petrol, lubricants, gas or similar flammable materials, even if the container 
has been empty for a considerable time. THERE IS A VERY HIGH RISK 
OF EXPLOSION. 

 

The operator must be aware of all the special regulations which he needs 
to conform to when welding in enclosed spaces with a high risk of 
explosion. 

 

To prevent electric shock, we strongly suggest the following rules:  

 

Do not work in a damp or humid environment. 

 

Do not use the welding machine if its cables are damaged in any way. 

 

Make sure that the earthing system of the electric equipment is correctly 
connected and operational. 

 

The operator must be insulated from the metal components connected to 
the return wire. 

 

The earthing of the piece being worked could increase the risk of injury to 
the operator. 

 

EN 60974-1 Standard:  Open-circuit voltage. During the operation of the 

Содержание PEGAS 160 E PFC

Страница 1: ...1 ALFA IN a s www alfain eu NA137 3 WELDING INVERTER PEGAS 160 E PFC OPERATING MANUAL...

Страница 2: ...ENT 7 5 1 ACCESSORIES TO ORDER 7 6 OPERATOR CONTROLS 8 6 1 FRONT PANEL 8 7 GETTING STARTED 9 7 1 GETTING STARTED MMA COATED ELECTRODE 9 7 2 GETTING STARTED TIG LIFT ARC 9 7 2 1 How to connect the gas...

Страница 3: ...electrodes up to 4 0 mm b TIG lift arc PEGAS 160 E PFC is equipped by system of Power Factor Correction PFC which enables operating on AC power supply of 95V 270V What are the advantages of PFC solut...

Страница 4: ...area of the risks that welding involves and to arrange to provide adequate protection equipment It is very important to arrange for sufficient ventilation especially when welding in enclosed spaces W...

Страница 5: ...C current 113V peak value and 80V effective 3 Torches held mechanically with increased protection for the operator DC current 141V peak value AC current 141V peak value and 100V effective In case 1 th...

Страница 6: ...ircuit voltage U20 V 71 0 71 0 Welding current DC 100 I2 U2 A V 60 22 4 100 14 0 80 23 2 100 14 0 Welding current DC 60 I2 U2 A V 80 23 2 115 14 6 110 24 4 110 14 4 Welding current DC x I2 U2 A V 30 1...

Страница 7: ...NI S777a Light Reactive Welding Helmet ALFA IN S777a GRAY 705 0307 Torch ABITIG 26 4m V 35 50 705 0308 Torch SR26 8m V 35 50 705 0172 Torch SR17 4m V 35 50 705 0173 Torch SR17 8m V 35 50 712 A011 Set...

Страница 8: ...ERATOR CONTROLS Fig 1 Main parts 6 1 FRONT PANEL Pos Description 1 LED ON 2 LED over heating 3 Current potentiometer 4 Method switch MMA electrode TIG 5 Cooling ribs 6 Panel quick connector 7 Mains so...

Страница 9: ...rode holder 7 2 GETTING STARTED TIG LIFT ARC Fit the TIG Torch to the minus terminal 5 and fasten it by turning the connector to the right Connect the work lead to positive terminal 6 and fasten it by...

Страница 10: ...ary for the control unit parts in the Welder If these parts are damaged for any reason replacement is recommended CAUTION Do not blow air into the welder during cleaning Blowing air into the welder ca...

Страница 11: ...If warranty is being sought please contact your ALFA IN product supplier for the warranty repair procedure ALFA IN warranty will not apply to Equipment that has been modified by any other party other...

Страница 12: ...nd electronic equipment waste and its implementation in accordance with national law electric tools that have reached the end of their service life must be collected separately and returned to an envi...

Отзывы: