Alesis M01 Скачать руководство пользователя страница 4

Confidential 

Alesis Service Manual 

8-31-0119-A 

Safety Suggestions 

 
Carefully read the applicable items of the operating instructions and these safety 
suggestions before using this product. Use extra care to follow the warnings 
written on the product itself and in the operating instructions. Keep the operating 
instructions and safety suggestions for reference in the future.   
 

1.  Power Source. The product should only be connected to a power supply which is described 

either in the operating instructions or in markings on the product. 

 
2.  Power Cord Protection. AC power supply cords should be placed such that no one is likely to 

step on the cords and such that nothing will be placed on or against them. 

 
3.  Periods of Non-use.  If the product is not used for any significant period of time, the product's 

AC power supply cord should be unplugged from the AC outlet. 

 
4.  Foreign Objects and Liquids.  Take care not to allow liquids to spill or objects to fall into any 

openings of the product. 

 
5.  Water or Moisture.  The product should not be used near any water or in moisture. 
 
6.  Heat.  Do not place the product near heat sources such as stoves, heat registers, radiators or 

other heat producing equipment. 

 
7.  Ventilation.  When installing the product, make sure that the product has adequate 

ventilation. Improperly ventilating the product may cause overheating, which may damage the 
product. 

 
8.  Mounting.  The product should only be used with a rack which the manufacturer 

recommends.  The combination of the product and rack should be moved carefully.  Quick 
movements, excessive force or uneven surfaces may overturn the combination which may 
damage the product and rack combination. 

 
9.  Cleaning.  The product should only be cleaned as the manufacturer recommends. 
 
10.  Service.  The user should only attempt the limited service or upkeep specifically described in 

the operating instructions for the user.  For any other service required, the product should be 
taken to an authorized service center as described in the operating instructions. 

 
11.  Damage to the Product.  Qualified service personnel should service the unit in certain 

situations including without limitation when: 
a.  Liquid has spilled or objects have fallen into the product, 
b.  The product is exposed to water or excessive moisture, 
c.  The AC power supply plug or cord is damaged, 
d.  The product shows an inappropriate change in performance or does not operate 

normally, or 

e.  The enclosure of the product has been damaged.

Содержание M01

Страница 1: ...ecipient you are hereby notified that any review dissemination distribution or duplication of this document is strictly prohibited If you are not authorized please contact Alesis and destroy all copies of this document You may contact Alesis at support Alesis com Copyright 2003 Alesis LLC ATTENTION THIS DOCUMENT CONTAINS SENSITIVE PROPRIETARY INFORMATION ALL RECIPIENTS MUST HAVE A CURRENT NON DISC...

Страница 2: ... to the Manual shall be solely your responsibility and Alesis shall have no liability for any such repairs or service work All such service or repairs are performed at the sole risk of the person performing the service or repairs You agree that all such work will be performed in a competent professional and safe manner at all times and to indemnify and fully hold Alesis and its successors and assi...

Страница 3: ...presence of important operating maintenance and servicing instructions in the literature which accompanies the product REPAIR BY ANY PERSON OR ENTITY OTHER THAN AN AUTHORIZED ALESIS SERVICE CENTER WILL VOID THE ALESIS WARRANTY PROVISION OF THIS MANUAL DOES NOT AUTHORIZE THE RECIPIENT TO COMPETE WITH ANY ALESIS DISTRIBUTOR OR AUTHORIZED REPAIR SERVICE CENTER IN THE PROVISION OF REPAIR SERVICES OR T...

Страница 4: ... stoves heat registers radiators or other heat producing equipment 7 Ventilation When installing the product make sure that the product has adequate ventilation Improperly ventilating the product may cause overheating which may damage the product 8 Mounting The product should only be used with a rack which the manufacturer recommends The combination of the product and rack should be moved carefull...

Страница 5: ...Easy to Use Easy to Understand User Interface Able to connect multiple units together to pass digital audio and power Width equivalent to a 1 3 U Rack Space Use of optional rack mount adapter Mechanical Size 15cm Lx 9 5cm Wx 4 6cm H Rack Spaces 1 space Weight 0 82kg MODEL MODFX ...

Страница 6: ...Confidential Alesis Service Manual 8 31 0119 A ALESIS ModFX Series M01 M14 ASSEMBLY PACKAGING ...

Страница 7: ... a Take off 4 pcs of knob on front panel 1 REMOVAL OF FRONT PANEL Fig 1 2 REMOVAL OF MAIN P C B Fig 2 a Take off unscrew 5 pcs of jack nuts on rear side of the bottom plate Fig 1 b Unscrew 1 pc of screw at bottom plate Fig 2 ...

Страница 8: ...Packing Instruction M01 14 ...

Страница 9: ...8 14 13 7 6 4 5 3 2 1 9 7 10 5 12 11 M01 M14 ALESIS EXPLODED VIEW ...

Страница 10: ...Confidential Alesis Service Manual 8 31 0119 A ALESIS ModFX Series M01 M14 TEST PROCEDURES ...

Страница 11: ...over is Removed Visually inspect all internal cables to make sure that they are installed correctly Diagnostic Mode 1 Turn all four knobs full left 2 Press and hold BYPASS while plugging in the P3 power supply to the DUT rear panel Potentiometers Test 3 Turn left knob to 9 o clock position 4 Turn left knob to full left position Verify that clip signal LED turns off 5 Turn left knob to 12 o clock p...

Страница 12: ...iagnostic mode Plug Power Cable into Studio 12R X3 or equivalent mixer Plug CD Player Outputs into DUT Inputs Plug DUT Outputs into X3 Inputs 1 2 Plug Headphones into X3 Headphone Output Audio Listening Test 1 Press BYPASS on DUT 2 Play music on CD player SECTION 3 link TEST Setup Procedures The ModFX link fixture consists of two ModFX that are known to be of good quality The two ModFX units are k...

Страница 13: ...ayer 6 Set X3 channels 1 2 faders to 0 dB Verify that audio sounds OK through headphones SECTION 4 VISUAL INSPECTION Setup Procedures Remove all Cables Visual Inspection Verify the following on the Complete Unit Check for any loose parts contained in the unit by picking up the box a rotating it gently in all directions Verify the following on the top plastic enclosure and bottom metal chassis Ther...

Страница 14: ...Confidential Alesis Service Manual 8 31 0119 A ALESIS ModFX Series M01 M14 SCHEMATIC AND PCB FILES ...

Страница 15: ...M01FP200A sch 1 Wed Apr 03 18 34 43 2002 ...

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ...Confidential Alesis Service Manual 8 31 0119 A ALESIS ModFX Series M01 M14 ECN HISTORY ...

Страница 22: ......

Страница 23: ......

Страница 24: ...Confidential Alesis Service Manual 8 31 0119 A ALESIS ModFX Series M01 M14 BOM ...

Страница 25: ...O UNFIXED LIST 1 KNOB DWI DIRECTION W SPRAY 2 5 1 PT131060501 KNOB BY PASS W SPRAY 1 6 1 PT131060601 KNOB VR W SPRAY PANTONE 877C 4 2 1 PT133000201 F PANEL W SPRAY PANTONE 877C 1 4 2 PT1330002 FRONT PANEL 1 1 RU1304403 CUSHION RUBBER 1 14 1 RU1310603 RUBBER 4 1 1 RU1330601 RUBBER BOTTOM 2 7 1 SC0306PBBI SCREW 1 9 1 REFER TO UNFIXED LIST 1 IO PCB ASSY 1 8 2 9 40 0259 IO PCB 1 2 0 09 0031 V RESISTOR...

Страница 26: ...05 RESISTOR 820 OHM SMD 1 R19 2 SC0308RIZI SCREW 4 J1 J8 1 REFER TO UNFIXED LIST 1 C PCB ASSY 1 11 2 9 40 0276 C PCB 1 2 0 17 0331 CHIP RESISTOR 4X330ohm1 16W 4 R01 R02 R03 R04 2 2 72 0339 I C LM339 2 U02 U03 2 3 02 0021 LED GREEN REFER TO PCB UNFIXED LIST 2 3 03 0001 LED TRI STATE 1 D010 2 6 02 0050 SWITCH TACT REFER TO PCB UNFIXED LIST 2 7 01 0038 RESONATOR 12MHZ 1 M1 2 REFER TO PCB UNFIXED LIST...

Страница 27: ...6 08 M08 6 13 9 79 0276 09 M09 4 6 9 79 0276 10 M10 6 13 9 79 0276 11 M11 6 13 9 79 0276 12 M12 7 12 9 79 0276 13 M13 2 6 9 79 0276 14 M14 4 8 IC 64K AT LOCATION U01 PCB ASS Y 9 79 0276 01 M01 9 61 0047 9 79 0276 08 M08 9 61 0054 9 79 0276 02 M02 9 61 0048 9 79 0276 09 M09 9 61 0055 9 79 0276 03 M03 9 61 0049 9 79 0276 10 M10 9 61 0056 9 79 0276 04 M04 9 61 0050 9 79 0276 11 M11 9 61 0057 9 79 027...

Страница 28: ...259 1 9 79 0276 06 2 PCS TW9 79 0276 07 M07ALE01 PT131060301 PT131060401 9 13 0023 9 79 0259 1 9 79 0276 07 2 PCS 2 PCS TW9 79 0276 08 M08ALE01 PT131060301 PT131060401 9 13 0024 9 79 0259 1 9 79 0276 08 2 PCS 2 PCS TW9 79 0276 09 M09ALE01 PT131060301 PT131060401 9 13 0025 9 79 0259 1 9 79 0276 09 2 PCS 1 PC TW9 79 0276 10 M10ALE01 PT131060301 PT131060401 9 13 0026 9 79 0259 2 9 79 0276 10 2 PCS 2 ...

Страница 29: ...50 0167 7 53 0174 M06ALE01 7 51 0113 LAC47ALE05 LAC47ALE21 7 50 0168 7 53 0175 M07ALE01 7 51 0114 LAC47ALE06 LAC47ALE22 7 50 0169 7 53 0176 M08ALE01 7 51 0115 LAC47ALE07 LAC47ALE23 7 50 0170 7 53 0177 M09ALE01 7 51 0116 LAC47ALE08 LAC47ALE24 7 50 0171 7 53 0178 M10ALE01 7 51 0117 LAC47ALE09 LAC47ALE25 7 50 0172 7 53 0179 M11ALE01 7 51 0118 LAC47ALE10 LAC47ALE26 7 50 0173 7 53 0180 M12ALE01 7 51 01...

Отзывы: